TU-E-217BCD-11: Evaluating the Performance of a Stationary Digital Breast Tomosynthesis System.

نویسندگان

  • A Tucker
  • E Gidcumb
  • J Shan
  • X Qian
  • F Sprenger
  • D Spronk
  • Y Zhang
  • D Kennedy
  • T Farbizio
  • C Ruth
  • Z Jing
  • J Lu
  • O Zhou
چکیده

PURPOSE In conventional Digital Breast Tomosynthesis (DBT) systems a single x-ray source moves over a limited angle arc. This leads to motion blurring in the projection images associated with x-ray source motion and total scan times. We have developed a stationary DBT (s-DBT) system which forgoes a rotating source for an array of carbon nanotube (CNT) based x-ray sources. Here we report the results of evaluating the performance and the optimization of image acquisition parameters of the s-DBT system. METHODS The s-DBT system consists of a linear source array with 31 x-ray generating focal spots distributed over a 30 degree angular span. The source array has been retrofitted onto a Hologic Selenia Dimensions DBT system. An American College of Radiology accreditation phantom was imaged to assess the quality of the reconstruction images in different configurations. A line wire phantom is used to measure the modulation transfer function (MTF). RESULTS For the standard imaging protocol, the system resolution along the scanning direction is increased from 3.0 cycles/mm in DBT to 4.2 cycles/mm in s-DBT at a magnification factor of 1.08. The MTF did not have a noticeable change between different configurations, whereas in DBT the MTF can be degraded for larger angular spans due to faster x-ray source motion. The overall image quality factor is found to be best for the configuration with a large angular span and intermittent number of projection views. CONCLUSIONS We demonstrated successful construction and operation of the s-DBT system integrating a CNT x-ray source array with a Hologic DBT system. The spatial resolution of the s-DBT system is demonstrated to be substantially increased over the corresponding DBT system. It was found that a configuration with a large angular span, an intermittent number of projection views, and an even dose distribution resulted in the best overall image quality. Hologic INC has provided the Hologic Selenia Dimensions used in the research. The project is supported by the National Cancer Institute under grant number U54CA119343 and R01CA134598 and the UNC University Cancer Research Fund. Dr. Xin Qian is supported by a fellowship from the Department of Defense under grant number BC087505.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Object-Oriented Simulator for 3D Digital Breast Tomosynthesis Imaging System

Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to...

متن کامل

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

TU-D-PinS Room/Hall E-01: Siemens Digital Breast Tomosynthesis: Design of a Wide Angle System & Quality Control.

This session along with the others on Digital Breast Tomosynthesis (DBT) offered at this years meeting as part of the Educational, Scientific and Partners in Solutions is intended to meet the FDA requirements for physicists to survey a DBT system. Specifically, this vendor offered session held as part of the Partners in Solutions is also meant to focus on those requirements. This session is bei...

متن کامل

Full-field breast tomosynthesis.

Breast tomosynthesis is a 3-dimensional (3-D) imaging technology that involves acquiring images of a stationary compressed breast at multiple angles during a short scan. The individual images are then reconstructed into a series of thin high-resolution slices that displayed individually or in a dynamic ciné mode. Tomosynthesis can reduce or eliminate the tissue overlap effect. While holding the...

متن کامل

Digital breast tomosynthesis: a pilot observer study.

OBJECTIVE The objective of our study was to assess ergonomic and diagnostic performance-related issues associated with the interpretation of digital breast tomosynthesis-generated examinations. MATERIALS AND METHODS Thirty selected cases were read under three different display conditions by nine experienced radiologists in a fully crossed, mode-balanced observer performance study. The reading...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part24  شماره 

صفحات  -

تاریخ انتشار 2012