A new suture needle for corneal surgery.
نویسنده
چکیده
IT occurred to me some time ago that, if one used a straight needle so that in placing sutures there was no bending force applied by the needle-holder, this needle could be greatly reduced in diameter. This smaller cross-section would in turn allow it to penetrate tough tissue such as the cornea much more easily. Further, I felt that with a straight needle one could place sutures much more accurately in that one could gauge the point of exit more exactly. For instance, in direct suturing of corneal grafts, one Wants to introduce the needle near the edge of the epithelial surface and to bring it out on the cut edge of the graft. It must not go through to the endothelial surface nor must it take too shallow a bite. With the normal curved needle this can be quite difficult to gauge, but with a straight needle the angle is easy to judge in order to bring it out at the correct depth. There is also no risk of this needle cutting out as there is with a curved needle going shallow. I therefore had a straight needle made from 15-gauge wire material which has a diameter of only 0 010 inches. It was 4 mm. long, triangular pointed, and flattened at the other end for the eye. For comparison it may be noted that the ordinary No. 6 curved eye needle is made from 10-gauge and the standard Jameson Evans corneal needle from 12-gauge wire (Evans, 1954). I have given these needles an extended trial for 8 or 9 months, using them particularly for suturing penetrating corneal grafts and for edge-to-edge suturing of cataract sections. I have also used Jameson Evans and Grieshaber needles during this period for comparison. In some corneal grafts with multiple sutures, I have put in some sutures with the straight and some with the curved needles in the same case. I have found the straight needles very satisfactory for the following reasons: (1) They penetrate the cornea more easily and cause much less trauma. (2) There is less tendency for the sutures introduced by them to cut out than for those introduced by curved needles. This has been proved in corneal grafts in which both types of needle have been used and sutures left in for up to 28 days. (3) They can be placed more accurately, and being so short they can be pulled through without difficulty and with no danger of injuring underlying structures
منابع مشابه
Corneal needle; a modification.
THE corneal needle recently described (Evans, 1954) has filled a need in corneal surgery and continues to give satisfactory results. The makerst have now suggested a modification which I find is an improvement. The new version of the n.edle has the eye placed sideways, that is, in the lateral plane instead of in the same plane as the blade, and the eye is grooved as before. It will be realized ...
متن کاملSuture fixation of a foldable acrylic intraocular lens for ectopia lentis.
A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-...
متن کاملCorneal Suturing Techniques
Surgical Indications • Congenital corneal disorders • Corneal dystrophies • Corneal degenerations • Corneal scarring/opacifi cation – Infection – Infl ammation – Trauma • Graft failure • Corneal decompensation – Pseudophakic – Aphakic – Iatrogenic – Dystrophic – Traumatic Surgical Instrumentation • Operating microscope • Microsuturing instruments – Fine-toothed 0.12-mm forceps – Fine-tip needle...
متن کاملNovel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot
PURPOSE To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). METHODS First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 su...
متن کاملBiomechanical simulation of needle insertion into cornea based on distortion energy failure criterion.
PURPOSE This paper is mainly about biomechanical behavior of needle insertion into cornea, and proposes a failure criterion to simulate the insertion process which has attracted considerable attention due to its importance for the minimally invasive treatment. METHODS In the process of needle insertion into cornea, tiny and complex insertion force is generated due to contact between needle an...
متن کاملSuture-related keratitis following cataract surgery caused by methicillin-resistant Staphylococcus aureus
A 54-year old-man presented with a two-day history of severe pain and decreased vision. Examination revealed a corneal ulcer associated with a loose suture from cataract surgery done approximately two years ago. The suture was removed and the patient was started on topic antibiotic treatment with cefazolin and gentamycin. Cultures revealed methicillin-resistant Staphylococcus aureus (MRSA). The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 41 1 شماره
صفحات -
تاریخ انتشار 1957