Comparison of fully porous-coated and hybrid hip resurfacing: a minimum 2-year follow-up study.
نویسندگان
چکیده
The purpose of this study was to compare clinical and radiological outcomes of the first 191 fully porous-coated hip resurfacing arthroplasties with 96 hybrid hip resurfacing arthroplasties performed during the same period at a minimum 2-year follow-up to evaluate the initial fixation of uncemented femoral resurfacing components. The results of this study indicate that fully porous-coated femoral resurfacing components can routinely achieve reliable fixation and provide similar initial results as have been achieved with cemented fixation. Long-term results are needed to determine which type of fixation is superior for the femoral hip resurfacing component.
منابع مشابه
The first 100 fully porous-coated femoral components in hip resurfacing.
UNLABELLED Uncemented fixation of implants to bone is a proven technology in traditional hip arthroplasty surgery. However, cement fixation is currently the standard method for the femoral component in hip resurfacing. The purpose of this study was to evaluate the performance of uncemented fixation of the femoral component in the first 100 fully porous-coated metal-on-metal hip resurfacing arth...
متن کاملResults of the Birmingham Hip Resurfacing dysplasia component in severe acetabular insufficiency: a six- to 9.6-year follow-up.
The dysplasia cup, which was devised as an adjunct to the Birmingham Hip Resurfacing system, has a hydroxyapatite-coated porous surface and two supplementary neutralisation screws to provide stable primary fixation, permit early weight-bearing, and allow incorporation of morcellised autograft without the need for structural bone grafting. A total of 110 consecutive dysplasia resurfacing arthrop...
متن کاملThe early results of metal-on-metal hip resurfacing - a prospective study at a minimum two-year follow-up.
Hip resurfacing has recently been offered as an attractive alternative to conventional total hip arthroplasty. This report evaluated the short-term functional outcome and longevity of a newer generation resurfacing device and includes the results of 228 consecutive hip resurfacing in 209 patients at a minimum of two-year follow-up. All resurfacing were performed by a single surgeon using a post...
متن کاملNo superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups
BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. METHODS T...
متن کاملMetal-on-metal hip resurfacing with an uncemented femoral component. A seven-year follow-up study.
BACKGROUND Metal-on-metal hip resurfacing with hybrid fixation has been introduced as an alternative to standard total hip arthroplasty, especially for young and active patients. There are few studies in the literature on the midterm results of cementless femoral side resurfacing. The purpose of this study was to present our seven-year clinical results of a series of twenty cementless metal-on-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Orthopedic clinics of North America
دوره 42 2 شماره
صفحات -
تاریخ انتشار 2011