Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results.

نویسندگان

  • T G Pait
  • O Al-Mefty
  • F A Boop
  • K I Arnautovic
  • S Rahman
  • W Ceola
چکیده

OBJECT The authors present a series of 16 patients who underwent inside-outside occipital and posterior cervical spine stabilization. METHODS In this technique, the screw was placed from the inside of the occiput to the outside. An articular (lateral) mass plate was contoured to the shape of the occipital bone and the cervical spine and affixed to the occiput with a flat-headed screw or stud placed through a burr hole in the calvaria with the flat head of the screw in the epidural space and the threads facing outward. The bone plate was then secured with a nut to the occipital screw and the cervical plate was attached to the spine with a bone screw that coursed through the plate and into the articular pillar. Our series included six children and 10 adults. In five patients, previous fusion had failed; in two patients spinal instability was secondary to Down's syndrome; two patients' instability was related to developmental anomalies; and in five patients spinal instability was due to the presence of tumor. One patient with rheumatoid arthritis had undergone a transoral procedure. Two patients had suffered traumatic fracture. Three patients died of causes unrelated to the procedure, one patient died of metastatic cancer, and one patient died in a long term care facility of cardiopulmonary complications. One patient with renal failure suffered a hemorrhage from an arteriovenous fistula after being treated with dialysis. In one child, a nut backed off after 3 months. The nut was reseated, and a maturing arthrodesis was present. CONCLUSIONS The authors conclude that the inside-outside occipitocervical fixation is an effective technique for stabilizing the cervical spine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Posterior Occipitocervical Angle and Surgical Outcomes for Occipitocervical Fusion

Study Type Retrospective cohort study. Introduction Craniocervical instability is a surgical disease, most commonly due to rheumatoid arthritis, trauma, erosive pathologies such as tumors and infection, and advanced degeneration. Treatment involves stabilization of the craniovertebral junction by occipitocervical instrumentation and fusion. However, the impact of the fixed occipitocervical angl...

متن کامل

Posterior Instrumentation for Occipitocervical Fusion

Since 1995, 29 consecutive patients with craniocervical spine instability due to several pathologies were managed with posterior occipitocervical instrumentation and fusion. Laminectomy was additionally performed in nineteen patients. The patients were divided in two groups: Group A which included patients managed with screw-rod instrumentation, and Group B which included patients managed with ...

متن کامل

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation dur...

متن کامل

History of instrumentation for stabilization of the subaxial cervical spine.

In the past several decades methods have been developed to stabilize the subaxial cervical spine both posteriorly and anteriorly. Methods of posterior stabilization have progressed from interspinous wiring, through facet wiring and sublaminar wiring, to the lateral mass screws with plates and rods that are in use today. Plates for anterior stabilization have evolved from rigid plates requiring ...

متن کامل

Biomechanical analysis of occipitocervical stability afforded by three fixation techniques.

BACKGROUND CONTEXT Occipital condyle screws appear to be a novel technique that demands biomechanical consideration. It has the potential to achieve fixation anterior to the axis of rotation while offering a point of fixation in line with the C1/C2 screws. PURPOSE To compare the segmental stability and range of motion (ROM) of standard occipitocervical (OC) screw/rod and plate constructs vers...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 90 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 1999