Technical Note
نویسندگان
چکیده
Luminol, leuchomalachite green, phenolphthalein, Hemastix, Hemident, and Bluestar are all used as presumptive tests for blood. In this study, the tests were subjected to dilute blood (from 1:10,000 to 1:10,000,000), many common household substance, and chemicals. Samples were tested for DNA to determine whether the presumptive tests damaged or destroyed DNA. The DNA loci tested were D2S1338 and D19S433. Leuchomalachite green had a sensitivity of 1:10,000, while the remaining tests were able to detect blood to a dilution of 1:100,000. Substances tested include saliva, semen, potato, tomato, tomato sauce, tomato sauce with meat, red onion, red kidney bean, horseradish, 0.1 M ascorbic acid, 5% bleach, 10% cupric sulfate, 10% ferric sulfate, and 10% nickel chloride. Of all the substances tested, not one of the household items reacted with every test; however, the chemicals did. DNA was recovered and amplified from luminol, phenolphthalein, Hemastix, and Bluestarr, but not from leuchomalachite green or Hemident.
منابع مشابه
Modeling and Control of Gas Turbine Combustor with Dynamic and Adaptive Neural Networks (TECHNICAL NOTE)
متن کامل
An Efficient Algorithm for Output Coding in Pal Based Cplds (TECHNICAL NOTE)
One of the approaches used to partition inputs consists in modifying and limiting the input set using an external transcoder. This method is strictly related to output coding. This paper presents an optimal output coding in PAL-based programmable transcoders. The algorithm can be used to implement circuits in PAL-based CPLDs.
متن کاملA Study of Dynamic Characteristics of a Multistory Building Using Ambient Vibration Tests (TECHNICAL NOTE)
Dynamic characteristics of a typical multistory building in Iran have been studied in two different stages of building construction, using ambient vibration tests. Finite element models have also been used to determine these characteristics and to verify test results. The results indicated the agreements and also differences between conventional theoretical models and the behaviour of real stru...
متن کاملAnatomical Repair of Stener-like Lesion of Medial Collateral Ligament: A case Series and Technical Note
Medial collateral ligament tears usually will be treated through non-surgical methods, but, in some cases such as thosewith tears at the distal insertion where the reduction could be blocked by the pes anserine tendons (Stener-like lesion), surgerywill be performed. Here, we present a surgical technique in such cases. In this retrospective case series, we describesix patients diagnosed with Ste...
متن کاملARTHROSCOPIC MODIFIED ALL-INSIDE LATERAL MENISCAL TEAR REPAIR USING TWO POSTERIOR PORTAL TECHNICAL NOTE
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کامل