Serratia marcescens: A Rare Cause of Recurrent Implantable Cardioverter Defibrillator Site Infection
نویسندگان
چکیده
We present a unique case of a patient who experienced recurrent infections of his implantable cardioverter defibrillator (ICD) site with the bacterium Serratia marcescens. This report highlights the virulence of this bacterium, its resistance to antibiotic therapy, and its ability to remain latent for prolonged periods between episodes of sepsis. It also demonstrates the merits of reimplanting devices at different sites in the context of Serratia marcescens infection.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملImplantable cardioverter defibrillator pocket infection caused by Stenotrophomonas maltophilia
Introduction: Stenotrophomonas maltophilia is an opportunistic gram-negative rod emerging as a cause of various multidrug-resistant infections. Case Report: We report a case of implantable cardioverter-defibrillator (ICD) pocket infection caused by S. maltophilia in an 85-year-old male. The patient recovered after ICD removal and antimicrobial therapy with ceftazidime. Conclusion: As ICD implan...
متن کاملAutomatic implantable cardioverter defibrillator pocket infection due to Providencia rettgeri: a case report
Coagulase-negative staphylococci and Staphylococcus aureus are the commonest pathogens involved in infections of pacemaker-defibrillator systems. Among causative Gram-negative bacteria, infections due to Klebsiella, Serratia, Pseudomonas, Acinetobacter and other species have been reported. We report herein a unique case of an automatic implantable cardioverter defibrillator infection due to Pro...
متن کاملCatecholaminergic Polymorphic Ventricular Tachycardia: A Rare Cause of Cardiac Arrest Following Blunt Chest Trauma.
UNLABELLED Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an electrophysiological disorder of a physically normal heart that occurs in children when the body is subjected to intense emotional or physical stress that causes adrenergic discharge. This troubling disease can be sporadic (spontaneous) or familial (genetic/inherited). Unfortunately, its associated ventricular tachyca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015