New insights into the atrial electrophysiology of rodents using a novel modality: the miniature-bipolar hook electrode.

نویسندگان

  • Yoram Etzion
  • Michal Mor
  • Aryeh Shalev
  • Shani Dror
  • Ohad Etzion
  • Amir Dagan
  • Ofer Beharier
  • Arie Moran
  • Amos Katz
چکیده

Studies of atrial electrophysiology (EP) in rodents are challenging, and available data are sparse. Herein, we utilized a novel type of bipolar electrode to evaluate the atrial EP of rodents through small lateral thoracotomy. In anesthetized rats and mice, we attached two bipolar electrodes to the right atrium and a third to the right ventricle. This standard setup enabled high-resolution EP studies. Moreover, a permanent implantation procedure enabled EP studies in conscious freely moving rats. Atrial EP was evaluated in anesthetized rats, anesthetized mice (ICR and C57BL6 strains), and conscious rats. Signal resolution enabled atrial effective refractory period (AERP) measurements and first time evaluation of the failed 1:1 atrial capture, which was unexpectedly longer than the AERP recorded at near normal cycle length by 27.2+/-2.3% in rats (P<0.0001; n=35), 31.7+/-8.3% in ICR mice (P=0.0001; n=13), and 57.7+/-13.7% in C57BL6 mice (P=0.015; n=4). While AERP rate adaptation was noted when 10 S1s at near normal basic cycle lengths were followed by S2 at varying basic cycle length and S3 for AERP evaluation, such rate adaptation was absent using conventional S1S2 protocols. Atrial tachypacing in rats shortened the AERP values on a timescale of hours, but a reverse remodeling phase was noted thereafter. Comparison of left vs. right atrial pacing in rats was also feasible with the current technique, resulting in similar AERP values recorded in the low right atrium. In conclusion, our findings indicate that in vivo rate adaptation of the rodent atria is different than expected based on previous ex vivo recordings. In addition, atrial electrical remodeling of rats shows unique remodeling-reverse remodeling characteristics that are described here for the first time. Further understanding of these properties should help to determine the clinical relevance as well as limitations of atrial arrhythmia models in rodents.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution mapping of scar-related atrial arrhythmias using smaller electrodes with closer interelectrode spacing.

BACKGROUND The resolution of mapping is influenced by electrode size and interelectrode spacing. Smaller electrodes with closer interelectrode spacing may improve mapping resolution, particularly in scar. The aims of this study were to establish normal electrogram criteria in the atria for both 3.5-mm electrode tip linear catheters (Thermocool) and 1-mm multielectrode-mapping catheters (Pentara...

متن کامل

Resolving Bipolar Electrogram Voltages During Atrial Fibrillation Using Omnipolar Mapping.

BACKGROUND Low-voltage-guided substrate modification is an emerging strategy in atrial fibrillation (AF) ablation. A major limitation to contemporary bipolar electrogram (EGM) analysis in AF is the resultant lower peak-to-peak voltage (Vpp) from variations in wavefront direction relative to electrode orientation and from fractionation and collision events. We aim to compare bipole Vpp with nove...

متن کامل

Electrogram fractionation: the relationship between spatiotemporal variation of tissue excitation and electrode spatial resolution.

BACKGROUND Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). METHODS AND RESULTS Using a computer model, we generated tissue activation patterns with increasi...

متن کامل

Results of short-term and long-term pulmonary vein isolation for paroxysmal atrial fibrillation using duty-cycled bipolar and unipolar radiofrequency energy.

BACKGROUND Electrical disconnection of the pulmonary veins (PV) plays an important role in the ablation of paroxysmal atrial fibrillation (AF). Antral ablation using a conventional steerable ablation catheter often is technically challenging and time consuming. METHODS Eighty-eight patients (mean age 58 +/- 11 years) with symptomatic paroxysmal AF underwent ablation with a circular mapping/ab...

متن کامل

Origin and Characteristics of High Shannon Entropy at the Pivot of Locally Stable Rotors: Insights from Computational Simulation

BACKGROUND Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiolog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 295 4  شماره 

صفحات  -

تاریخ انتشار 2008