Behavior of concentrically loaded CFT braces connections
نویسندگان
چکیده
Concrete filled tubes (CFTs) composite columns have many economical and esthetic advantages, but the behavior of their connections is complicated. Through this study, it is aimed to investigate the performance and behavior of different connection configurations between concrete filled steel tube columns and bracing diagonals through an experimental program. The study included 12 connection subassemblies consisting of a fixed length steel tube and gusset plate connected to the tube end with different details tested under half cyclic loading. A notable effect was observed on the behavior of the connections due to its detailing changes with respect to capacity, failure mode, ductility, and stress distribution.
منابع مشابه
Seismic Behavior of Asymmetric Two-Story X-braced Frames
Concentrically braced frames (CBFs) are one of the efficient lateral load resisting systems in high seismicity regions. One of the common problems with the use of concentrically braced frames is limitation in the architectural application and position of the openings. Two-story X braced frames have more advantages than other configurations of concentrically braced frames, since in many cases th...
متن کاملThe Effects of Internal and External Stiffeners on Hysteretic Behavior of Steel Beam to CFT Column Connections
This study focuses on performance of H-shaped steel beams to CFT column rigid connections. To this end, the effects of internal and external stiffeners on hysteretic behavior of connections were studied. Comparative numerical analyses carried out on eight different connections. To this end finite element models were prepared using ANSYS and nonlinear cyclic analyses carried out. Results of this...
متن کاملAnalytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملSeismic Retrofitting of Steel Frames with Buckling Restrained and Ordinary Concentrically Bracing Systems with Various Strain Hardening and Slenderness Ratios
The present study assesses the seismic performance of steel moment resisting frames (SMFs) retrofitted with different bracing systems. Two structural configurations were utilized: ordinary concentrically braces (OCBFs), buckling-restrained braces (BRBFs). A 7-story and 18-story steel perimeter SMFs were designed with insufficient lateral stiffness to satisfy code drift limitations in high seism...
متن کاملEvaluating the Performance of the Buckling Restrained Braces in Tall Buildings with peripherally braced frames
In recent years, seismic design of structures has been undergoing significant changes due to increasing demand for optimization and minimizing the level of damage and reducing the cost of structural repairs. Development of analytical methods and remarkable improvements of computer performance have been among the factors which influenced the design of structures. A lot of research has been condu...
متن کامل