Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: comparison with conventional digital subtraction angiography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE 3D computed tomographic angiography (3DCTA) has been used recently for the evaluation of intracerebral aneurysms, but it is difficult to use this technique to visualize aneurysms near the base of the skull because of the presence of bone. Subtracted 3DCTA could replace digital subtraction angiography (DSA) for evaluation of aneurysms near the base of the skull if the 2 methods were to give similar results. The aim of this study was to compare the evaluation of aneurysms of the internal carotid artery (ICA) near the base of the skull by subtracted 3DCTA and DSA. METHODS CTA and DSA were obtained in 25 patients with unruptured aneurysms of the ICA. To create subtracted 3DCTA images, we used a volume subtraction (VS) method, wherein nonenhanced volume data are subtracted from enhanced volume data. CTA and DSA were reviewed by 2 neuroradiologists who performed the detection and characterization of aneurysms of the ICA by using 2D multiplanar reformatted (MPR) and VS- and nonsubtracted (NS)-3DCTA images with volume rendering techniques. RESULTS DSA detected 29 aneurysms in the 25 patients. VS-3DCTA detected all 29 aneurysms in the 25 patients and was equivalent to DSA for evaluating their characteristics (location, size, and direction). NS-3DCTA detected 19 (1 cavernous, 4 ophthalmic, 1 superior hypophyseal, 7 posterior communicating, and 6 anterior choroidal artery) of these 29 aneurysms, but it could not characterize ophthalmic and superior hypophyseal artery aneurysms because they were only partly visible on NS-3DCTA because of bony structures. 2D-MPR images detected all but the small aneurysms (24 of 29 detected). VS-3DCTA and 2D-MPR could visualize all branching arteries (ophthalmic, posterior communicating, and anterior choroidal) detected by DSA, but NS-3DCTA could not visualize ophthalmic arteries because of the presence of bony structures. CONCLUSION VS-3DCTA can be used as an alternative to DSA for preoperative examination of aneurysms near the skull base, where it provides equivalent identification and characterization.
منابع مشابه
Comparison of 64 Dedector Cranial CT Angiography with Intra-Arterial DSA For Detection of Intracranial Aneurysms
The purpose of our study was to compare findings of 64 detector cranial computed tomographic angiography (CTA) and conventional digital subtraction angiography (DSA) mainly in patients with acute subarachnoid hemorrhage (SAH) headache and diplopia. Between March 2007 and May 2009, 65 consecutive patients were admitted with clinical symptoms and signs of intracranial aneurysm. 44 of 67 detected ...
متن کاملSimultaneous bilateral internal carotid artery 3D rotational angiography.
We simultaneously injected both internal carotid arteries (ICAs) during 3D rotational digital subtraction angiography in a patient with a ruptured anterior communicating artery (Acom) aneurysm and vasospasm. Shaded surface display (SSD) images from this acquisition provided more anatomic detail than did SSD images created from individual ICA 3D rotational digital subtraction angriography. In th...
متن کاملBone-subtraction CT angiography for the evaluation of intracranial aneurysms.
PURPOSE CT angiography (CTA) has been established for detection and therapy planning of intracranial aneurysms. The analysis of aneurysms at the level of the skull base, however, remains difficult because bone prevents a free view. We report initial clinical results of an approach for automatic bone elimination from CTA data. MATERIAL AND METHODS Before the bone-removal process 2 datasets are...
متن کاملDiagnostic Accuracy of Magnetic Resonance Angiography for Cerebral Aneurysms in Correlation With 3D–Digital Subtraction Angiographic Images
Background and Purpose—We investigated the sensitivity of 3D–time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. Methods—3D-TOF MRA was performed in 82 patient...
متن کاملVolume subtraction three-dimensional CT angiography for cerebrovascular disease: report of two cases.
We report two cases in which volume subtraction three-dimensional CT angiography (VS-3DCTA) was used for cerebral aneurysm and vascular stenosis with intramural calcification. Case 1: VS-3DCTA with volume rendering clearly showed carotid cave aneurysm of the internal carotid artery. The location and size of the aneurysm was confirmed by digital subtraction angiography (DSA). In evaluation of th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2006