Detection of Heart Shunts by Means of 12511

نویسندگان

  • Ismael Mena
  • Pablo Thomsen
چکیده

Prinzmetal et a!, used 24Na for this purpose (1), while others used al bumin 1311 (2). With more extensive experience, procedures improved over the years until, in 1958, Pritchard et al (3) reported an effective method for the external precordial detection and determination of cardiac output with albumin †̃@†̃I. During this time, a good correlation with dye dilution technique by means of arterial puncture was also noted. Later, Vernejoul (4) used 1321for this same purpose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Experience with Hydrogen as an Indicator of Left-to-right Shunts.

Detection of intracardiac shunts by means of conventional oximetry, dye dilution curves, nitrous oxide, or krypton gas tests, may be hampered by lack of sensitivity of the method, cost, or complexity of equipment and unreliability of the results. The hydrogen technique proposed by Clark and Bargeron (1959a, b) and Bargeron, Clark, and McArthur (1960) seems to obviate these disadvantages. The fo...

متن کامل

Precordial counting: evaluation and comparison of iodine-131 labelled albumin and technetium-99m in detection of left-to-right shunts.

a single gamma ray. Investigations were done to establish normal values and those in patients who had either rheumatic or congenital heart disease. All left-to-right shunts were confirmed at cardiac catheterization. False negative results were rare but false positive results can occur in the presence of congestive cardiac failure. It is possible to detect left-to-right shunts with a pulmonary t...

متن کامل

Prevalence and Etiology of Heart Murmurs in 2-24-Months-Old Infants Kerman, Iran

Background & aim: Congenital heart disease is one of the most common malformations at birth that require timely recognition and treatment. The aim of this study was to determine the prevalence and etiology of detected heart murmurs and association between congenital heart disease and heart murmurs. Recognition of murmurs etiology would help us to manage and treat them properly. Methods: In this...

متن کامل

The krypton85 inhalation test for the detection of left-to-right shunts.

One of the primary reasons for performing cardiac catheterization in patients known to have, or suspected of having, congenital heart disease is to determine whether a left-to-right shunt is present and the site at which it enters the right side of the heart. Although a variety of techniques for the detection of such shunts has been developed (Wood et al., 1957, 1958; Zimmerman, 1959; Braunwald...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006