Enhanced real-time cursor control algorithm, based on the spectral analysis of electromyograms.
نویسندگان
چکیده
This paper presents a new version of an EMG-based, hands-free, cursor control system, and compares its performance to that of a previous version. Both systems use classification algorithms that rely on the periodogram estimation of the power spectral density (PSD) of electromyogram (EMG) signals from muscles in the face. The older system requires three electrodes for EMG input, and utilizes an algorithm that calculates partial power accumulations over the frequency ranges of 0Hz - 145Hz and 145Hz - 600Hz in the PSDs of the EMG signals. The new system requires four electrodes for EMG input, and utilizes an algorithm that calculates mean power frequency (MPF) values to assist in distinguishing the cranial muscle that contracted. An experiment was devised to gauge the point-and-click capabilities of both systems. The experimental results were evaluated using Fitts' Law analysis. The results show that the new algorithm provides improved point-and-click performance over the old algorithm.
منابع مشابه
Electromyograms as Physiological Inputs that Provide Efficient Computer Cursor Control
This paper presents a new algorithm to translate electromyogram (EMG) signals, produced during facial muscle contractions, into computer cursor actions. These cursor actions are: left, right, up, down and left-click. The translation is performed in real-time and the classification of the EMG signals is based on features derived from the spectral analysis of the electromyograms. We have sought t...
متن کاملControl of a 2-DoF robotic arm using a P300-based brain-computer interface
In this study, a novel control algorithm, based on a P300-based brain-computer interface (BCI) is fully developed to control a 2-DoF robotic arm. Eight subjects including 5 men and 3 women perform a 2-dimensional target tracking in a simulated environment. Their EEG (Electroencephalography) signals from visual cortex are recorded and P300 components are extracted and evaluated to perform a real...
متن کاملChaotic dynamic analysis and nonlinear control of blood glucose regulation system in type 1 diabetic patients
In this paper, chaotic dynamic and nonlinear control in a glucose-insulin system in types I diabetic patients and a healthy person have been investigated. Chaotic analysis methods of the blood glucose system include Lyapunov exponent and power spectral density based on the time series derived from the clinical data. Wolf's algorithm is used to calculate the Lyapunov exponent, which positive val...
متن کاملReliability Analysis of Corroded Reinforced Concrete Beams Using Enhanced HL-RF Method
Steel corrosion of bars in concrete structures is a complex process which leads to the reduction of the cross-section bars and decreasing the resistance of the concrete and steel materials. In this study, reliability analysis of a reinforced concrete beam with corrosion defects under the distributed load was investigated using the enhanced Hasofer-Lind and Rackwitz-Fiessler (EHL-RF) method base...
متن کاملControl Simulation and Experimental Verification of Maximum Power Point Tracking Based on RT-LAB (TECHNICAL NOTE)
The maximum power point tracking (MPPT) control in the Photovoltaic system is the key control technology, however present controller has the disadvantages of long development cycle, high cost and complex verification, and there are some disadvantages carrying out totally physical simulation or totally digital simulation of different control algorithms. This paper carried out design of hardware ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical sciences instrumentation
دوره 42 شماره
صفحات -
تاریخ انتشار 2006