A novel approach to in vivo mitral valve stress analysis.

نویسندگان

  • Chun Xu
  • Clay J Brinster
  • Arminder S Jassar
  • Mathieu Vergnat
  • Thomas J Eperjesi
  • Robert C Gorman
  • Joseph H Gorman
  • Benjamin M Jackson
چکیده

Three-dimensional (3-D) echocardiography allows the generation of anatomically correct and time-resolved geometric mitral valve (MV) models. However, as imaged in vivo, the MV assumes its systolic geometric configuration only when loaded. Customarily, finite element analysis (FEA) is used to predict material stress and strain fields rendered by applying a load on an initially unloaded model. Therefore, this study endeavors to provide a framework for the application of in vivo MV geometry and FEA to MV physiology, pathophysiology, and surgical repair. We hypothesize that in vivo MV geometry can be reasonably used as a surrogate for the unloaded valve in computational (FEA) simulations, yielding reasonable and meaningful stress and strain magnitudes and distributions. Three experiments were undertaken to demonstrate that the MV leaflets are relatively nondeformed during systolic loading: 1) leaflet strain in vivo was measured using sonomicrometry in an ovine model, 2) hybrid models of normal human MVs as constructed using transesophageal real-time 3-D echocardiography (rt-3DE) were repeatedly loaded using FEA, and 3) serial rt-3DE images of normal human MVs were used to construct models at end diastole and end isovolumic contraction to detect any deformation during isovolumic contraction. The average linear strain associated with isovolumic contraction was 0.02 ± 0.01, measured in vivo with sonomicrometry. Repeated loading of the hybrid normal human MV demonstrated little change in stress or geometry: peak von Mises stress changed by <4% at all locations on the anterior and posterior leaflets. Finally, the in vivo human MV deformed minimally during isovolumic contraction, as measured by the mean absolute difference calculated over the surfaces of both leaflets between serial MV models: 0.53 ± 0.19 mm. FEA modeling of MV models derived from in vivo high-resolution truly 3-D imaging is reasonable and useful for stress prediction in MV pathologies and repairs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Stress Immunization on Psychological Well-Being, Depression and Blood Sugar in Pregnant Women with Mitral Valve Prolapse

Introduction: Pregnancy puts stress on the heart and circulatory system. This stress is more common in women with heart problems such as mitral valve prolapse. Stress and its resulting stress in pregnant women with mitral valve prolapse appear to cause many psychological and physiological complications such as decreased psychological well-being, depression and changes in blood sugar levels. How...

متن کامل

SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY

BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Marcus-gunn phenomenon with- mitral valve prolapse

Marcus-gunn phenomenon is a congenital and sometimes hereditary anomaly, in which a ptotic eyelid retracts momentarily when the mouth is open, or the jaw is moved. These associated movements attributed to abnormal connections between the central mechanisms innervating the pterygoid and elevator muscles. Sometimes this anomaly is associated with dual,s retraction syndrome, duplex kindneys and ur...

متن کامل

An inverse modeling approach for stress estimation in mitral valve anterior leaflet valvuloplasty for in-vivo valvular biomaterial assessment.

Estimation of regional tissue stresses in the functioning heart valve remains an important goal in our understanding of normal valve function and in developing novel engineered tissue strategies for valvular repair and replacement. Methods to accurately estimate regional tissue stresses are thus needed for this purpose, and in particular to develop accurate, statistically informed means to vali...

متن کامل

Surgical Treatment of Rheumatic Mitral Valve Lesions in Children and Adolescents

Rheumatismal lesions of the mitral valve a!I'e rare under the age of six and surgical iruter­vention in symptomatic patients is an academic problem. Early surgical treatment has been done to prevent serious changes and unrevers­ib1e complications o.f the heart and lungs.  From April 71 until April 74, thirty-five pati­ent, ranging between 8-18 years of age, suffer­ing of <lifferents heart ,tro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 299 6  شماره 

صفحات  -

تاریخ انتشار 2010