Theoretical evaluation and comparison of fast chemical shift imaging methods.
نویسندگان
چکیده
Magnetic resonance chemical shift imaging (CSI) is becoming the method of choice for localized NMR spectroscopic examinations, allowing simultaneous detection of NMR spectra from a large number of voxels. The main limitation of these methods is their long experimental duration. A number of fast CSI experiments have been presented, promising to reduce that duration. In this contribution the criteria for evaluating and optimizing the sensitivity of fast CSI experiments are elaborated. For a typical experiment in the human brain, the performance of various methods is compared. While conventional CSI provides optimal sensitivity per unit time, it is shown in which circumstances fast sequences allow a shorter experimental duration. Using these results, the best method for any experimental requirements can be selected.
منابع مشابه
Nano Theoretical Study of NMR Shielding Tensors on Ginger Plant
In this research, the Magnetite nanoparticles (Fe304) were prepared by coprecipitation of Fe- andGinger is a well known spice and flavoring agent which has also been used in traditional medicine inmany countries. Ginger contains essential oils including gingerol and zingiberene. It also containspungent principles such as zingerone, and shogaol. In the paper six theoretical methods were used toc...
متن کاملQuantum Mechanics-Molecular Mechanics Model Study of some Antibiotics and Vitamins in Gas Phases: Investigation of Energy and NMR Chemical Shift
The combination of Quantum Mechanics (QM) and Molecular Mechanics (MM) methods hasbecome alternative tool for many applications that pure QM and MM could not be suitable.The QM/MM method has been used for different type of problems, for example: structuralbiology, surface phenomena, and liquid phase. In this paper we have performed these methods forsome antibiotics and vitamins and then we comp...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملQuantum Chemical Modeling of 1-(1, 3-Benzothiazol-2-yl)-3-(thiophene-5-carbonyl) thiourea: Molecular structure, NMR, FMO, MEP and NBO analysis based on DFT calculations
In the present work, the quantum theoretical calculations of the molecular structure of the 1-(1, 3-Benzothiazol-2-yl)-3-(thiophene-5-carbonyl) thiourea has been predicted and are evaluated using Density Functional Theory (DFT) in gas phase. The geometry of the title compound was optimized by B3LYP/6-311+G and B3LYP/6-311+G* methods and the experimental geometrical parameters of the title compo...
متن کاملNMR and NBO Calculation of Broccoli Calm: Nano Physical Parameter Study
Sulforaphane, an isothiocyanate found in broccoli and other cruciferous vegetables. it is an antioxidantand anti-cancer agent, and reduces blood pressure, and also has anti-allergic Effects.In this article, six theoretical methods have been used for calculation of physical parameters insolforaphane and several similar compounds. We calculated physical parameters like atomic charges.energy (AE) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 129 2 شماره
صفحات -
تاریخ انتشار 1997