Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer.

نویسندگان

  • J J Pillow
  • H Ljungberg
  • G Hülskamp
  • J Stocks
چکیده

Accurate, reproducible and portable bedside monitoring of lung volume could potentially facilitate the early recognition of both under and overinflation of the lungs in ventilated and nonventilated subjects. This study asked whether a prototype portable ultrasonic flow meter provided valid and reliable measurements of functional residual capacity (FRCUS) when compared to those obtained using a mass spectrometer (FRCMS) in nonventilated healthy infants. Paired, randomised measurements of FRCMS and FRCUS were obtained using the sulphur hexafluoride (SF6) multiple-breath washout technique in 23 healthy infants with a median (range) postnatal age of 34.6 (1.3-92.6) weeks and weight of 8.3 (3.9-11.7) kg. FRCUS was on average 5.7%, (95% CI: 1.0-10.4%) less than FRCMS equating to a difference of approximately 1 mL x kg(-1). The 95% limits of agreement (LA) between the two techniques were relatively wide (95% LA: -17.5% to 29%), although in keeping with previously reported within-patient variability for lung volume measurements. There was no significant difference between the within subject coefficient of variation for FRCMS (3.7%) and FRCUS (5.2%). The ultrasonic flow meter used in this study provides repeatable measurements of functional residual capacity in spontaneously breathing healthy infants that approximate those obtained during mass spectrometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants.

Small airway disease in infants is characterised by abnormal lung volume and uneven ventilation distribution. An inert tracer gas washin/washout technique using a pulsed ultrasonic flow meter is presented to measure functional residual capacity (FRC) and ventilation distribution in spontaneously breathing and unsedated infants. With a pulsed ultrasound sent through the main stream of the flow m...

متن کامل

Normative data for lung function and exhaled nitric oxide in unsedated healthy infants.

Despite association with lung growth and long-term respiratory morbidity, there is a lack of normative lung function data for unsedated infants conforming to latest European Respiratory Society/American Thoracic Society standards. Lung function was measured using an ultrasonic flow meter in 342 unsedated, healthy, term-born infants at a mean ± sd age of 5.1 ± 0.8 weeks during natural sleep acco...

متن کامل

Lung Function in African Infants: A Pilot Study

BACKGROUND The burden of childhood respiratory illness is large in low and middle income countries (LMICs). Infant lung function (ILF) testing may provide useful information about lung growth and susceptibility to respiratory disease. However, ILF has not been widely available in LMICs settings where the greatest burden of childhood respiratory disease occurs. AIM To implement and evaluate a ...

متن کامل

Validation of a photoacoustic gas analyser for the measurement of functional residual capacity using multiple-breath inert gas washout.

BACKGROUND The respiratory mass spectrometer is the current gold-standard technique for performing multiple-breath inert gas washout (MBW), but is expensive and lacks portability. A number of alternative techniques have recently been described. OBJECTIVES We aimed to validate, using an in vitro lung model, an open-circuit MBW system that utilises a portable photoacoustic gas analyser, with su...

متن کامل

Pediatric Pulmonology 41:1218–1225 (2006) Multiple Breath Washout With a Sidestream Ultrasonic Flow Sensor and Mass Spectrometry: A Comparative Study

Over recent years, there has been renewed interest in the multiple breath wash-out (MBW) technique for assessing ventilation inhomogeneity (VI) as ameasure of early lung disease in children. While currently considered the gold standard, use of mass spectrometry (MS) to measure MBW is not commercially available, thereby limiting widespread application of this technique.Amainstreamultrasonic flow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 2004