Evaluation of two rapid methods for identification of commonly encountered nonfermenting or oxidase-positive, Gram-negative rods.

نویسنده

  • H Dowda
چکیده

The ability of the expanded API-20E and the Oxi-Ferm System to identify 176 isolates of nonfermenting or oxidase-positive, gram-negative rods from 17 species or groups was studied. The expanded API-20E, without referral to a computer reference center, was able to identify 61.4% of the isolates to the species level. If reference to the computer center was utilized, an additional 25% could be identified. Of the isolates examined, 13.6% were misidentified, partially identified, or assigned no identification. Those assigned to the incorrect genus constituted 0.5% of the isolates tested; those assigned to the correct genus, but the wrong species, constituted 0.5%; 4.5% were placed in the correct genus with no species given; and 7.9% were assigned no identification. The Oxi-Ferm System was able to assign 75% of the isolates to the correct species without further testing, and an additional 19.3% required additional testing for correct identification. Those assigned to the incorrect genus represented 3.4% of the isolates tested; 1.1% were assinged to the correct genus, but the wrong species; and 1.1% were assigned to the correct genus, with no species indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four methods for identification of gram-negative nonfermenting rods: organisms more commonly encountered in clinical specimens.

Four commercial kits, Oxi/Ferm (OF), API 20E (AP), Minitek (MT; BBL Microbiology Systems), and Flow N/F (NF), were evaluated, without additional tests, for identification of 258 gram-negative nonfermentative rods. OF and MT were read after 48 h of incubation, and AP and NF were read after both 24 and 48 h of incubation, respectively. Overall, OF correctly identified 51% of strains, with 46% as ...

متن کامل

Evaluation of the rapid NFT system for identification of gram-negative, nonfermenting rods.

This study evaluated the ability of the Rapid NFT system (API System SA, Montalieu-Vercieu, France) to accurately identify 262 clinically isolated, gram-negative, nonfermentative rods without additional tests. Identifications were classified as correct; low discrimination, with a spectrum of two or more possibilities (additional tests necessary for accurate identification); and incorrect. Corre...

متن کامل

Superiority of molecular techniques for identification of gram-negative, oxidase-positive rods, including morphologically nontypical Pseudomonas aeruginosa, from patients with cystic fibrosis.

Phenotypic identification of gram-negative bacteria from Cystic Fibrosis (CF) patients carries a high risk of misidentification. Therefore, we compared the results of biochemical identification by API 20NE with 16S rRNA gene sequencing in 88 gram-negative, oxidase-positive rods, other than morphologically and biochemically typical P. aeruginosa, from respiratory secretions of CF patients. The A...

متن کامل

Biochemical and susceptibility tests useful for identification of nonfermenting gram-negative rods.

Six hundred nineteen strains of nonfermenting gram-negative rods were tested for alkaline phosphatase, benzyl-arginine arylamidase, pyrrolidonyl arylamidase, ethylene glycol acidification, and susceptibility to desferrioxamine and colistin. The results were highly discriminant. Therefore, the proposed tests may be helpful for the identification of this group of organisms.

متن کامل

Ability of the MicroScan rapid gram-negative ID type 3 panel to identify nonenteric glucose-fermenting and nonfermenting gram-negative bacilli.

The MicroScan Rapid Neg ID3 panel is designed for the identification of Enterobacteriaceae and nonenteric glucose-fermenting and nonfermenting gram-negative bacilli. We evaluated this panel for its ability to identify gram-negative non-Enterobacteriaceae bacteria. A total of 134 strains, representing 26 genera and 42 species, were taken from storage at -70(o)C, passaged three times before testi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 1977