Digital angiographic assessment of the physiological changes to the regional microcirculation induced by successful coronary angioplasty.
نویسندگان
چکیده
BACKGROUND Impulse response analysis of digital coronary angiographic images calculates a parameter known as the mean transit time of the microcirculation (Tmicro). This has been shown to accurately assess the regional microcirculatory response to proximal stenosis in relation to flow. Our goal was to apply impulse response analysis to patients undergoing successful angioplasty and to quantify the induced physiological changes with respect to quantitative angiographic measurements of stenosis dimensions. METHODS AND RESULTS We studied 24 patients before and after successful single-vessel percutaneous transluminal coronary angioplasty (PTCA). Minimal luminal stenosis area was increased from 0.9 +/- 0.6 before PTCA to 4.1 +/- 1.3 mm2 after PTCA (P < .0001). In all patients this was accompanied by an increase in the inverse of Tmicro (Tmicro-1), from 8.5 +/- 3.0 to 26.5 +/- 9.0 min-1 (P < .0001) with a linear correlation between Tmicro-1 and minimal luminal stenosis area (r = .73; SEE = 7.74). Stenosis flow reserve, estimated by integration of stenosis dimensions, increased in all patients from 1.8 +/- 1.0 to 4.5 +/- 0.4 after PTCA (P < .01). A comparison of Tmicro-1 with stenosis flow reserve revealed a nonlinear relation. In 16 patients undergoing PTCA of the left anterior descending or circumflex artery, contrast injections into the left main stem allowed simultaneous measurements of Tmicro-1 in the adjacent, nonstenotic artery. Adjacent artery Tmicro-1 did not change after PTCA (25.8 +/- 6.2 compared with 25.6 +/- 6.8 min-1 before PTCA; P = NS); moreover, Tmicro-1 of the dilated artery measured after PTCA was equivalent to the nonstenotic adjacent artery, indicating normalization of microcirculatory responses. CONCLUSIONS These data suggest that Tmicro-1 determined by digital angiographic impulse response analysis of a single contrast injection under resting flow conditions may be a practical method to assess the regional microcirculatory response to changes in stenosis severity effected by coronary angioplasty.
منابع مشابه
Detection of Autoregulatory Changes in Nonstenotic Coronary Arteries Induced by Collateral Flow to Adjacent Stenotic Arteries
Background Our study compares the effect of acute proximal stenosis of a coronary artery supplying a myocardial perfusion bed with that of stenosis of an adjacent artery resulting in collateral flow diversion supplied by the same perfusion bed. These alterations in coronary physiology were quantified by digital angiographic impulse response analysis of contrast material mean transit time for th...
متن کاملDigital angiographic impulse response analysis of regional myocardial perfusion. Detection of autoregulatory changes in nonstenotic coronary arteries induced by collateral flow to adjacent stenotic arteries.
BACKGROUND Our study compares the effect of acute proximal stenosis of a coronary artery supplying a myocardial perfusion bed with that of stenosis of an adjacent artery resulting in collateral flow diversion supplied by the same perfusion bed. These alterations in coronary physiology were quantified by digital angiographic impulse response analysis of contrast material mean transit time for th...
متن کاملComparison of the effect of aromatherapy with geranium and lemon essential oil on situational anxiety and physiological Indices of patients after coronary angioplasty
Introduction: Postoperative anxiety, such as coronary artery bypass graft surgery, is one of the most common stressors in this group of patients, which can endanger their physical and mental health. The aim of this study was to compare the effect of aromatherapy with geranium and lemon essential oil on situational anxiety and physiological indices of patients after coronary angioplasty. Materi...
متن کاملValue of coronary stenotic flow velocity acceleration in prediction of angiographic restenosis following balloon angioplasty.
INTRODUCTION Quantitative angiographic assessment after balloon angioplasty is a poor predictor of immediate and long-term outcome. However, the measurement of blood flow velocity during angioplasty has been proved clinically useful. AIMS To analyse the value of the maximal stenotic flow velocity and the presence of stenotic flow velocity acceleration (aSV) for the long-term outcome after bal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 90 1 شماره
صفحات -
تاریخ انتشار 1994