SU-E-T-217: Automated Data Mining of Lung SBRT Cases for Predicting Dosimetric Indices in Prospective Plans.

نویسندگان

  • T Atwood
  • L Xing
  • D Hristov
چکیده

PURPOSE To develop an automated technique for evaluating lung stereotactic body radiotherapy (SBRT) plan quality and predicting achievable lung dose constraints. METHODS We examined the workflow scripting capabilities of a radiation oncology software package (MIM Software Inc) for automatically generating mean dose gradients and overlap volume histograms (OVHs) for lung SBRT plans. Mean dose gradients were created to assess plan quality by quantifying the dose fall-off from the planning target volume (PTV) into the ipsilateral lung. OVHs were created to evaluate potential predictors of achievable lung dose constraints by measuring the amount of ipsilateral lung volume overlapping the uniformly expanded PTV. Based on the knowledge that OVHs will depend on the size and spatial relationship of the lung and PTV structures, we hypothesize that OVH-derived indices will therefore serve as predictors of achievable lung dose. The workflow scripts were evaluated in a pilot study of 10 lung SBRT plans (50 Gy in 5 fractions) with varying PTV sizes and locations. RESULTS The scripted workflows were successful in automatically generating mean dose gradients and OVHs for the PTV and ipsilateral lung. The workflows were able to produce the aforementioned data in a matter of seconds (per patient), which would have otherwise been excessively time consuming and labor intensive. From the pilot study, the average mean dose gradient was - 4.1 ± 0.6, indicating that all evaluated patients had similar and acceptable plan quality. Furthermore, the OVH data indicated that a 0 mm PTV expansion and a 10 mm PTV expansion correlated with the mean lung dose (correlation coefficients of 0.71 and 0.56, respectively). CONCLUSIONS Our current data demonstrate that mean lung dose correlates to multiple OVH indices. These results indicate that automated large-scale mining of retrospective data is a highly promising approach for predicting dosimetric indices in prospective lung SBRT plans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Feasibility of Dose Escalation Using SBRT Boost for Stage III Non-Small Cell Lung Cancer

PURPOSE Standard chemoradiation therapy for stage III non-small cell lung cancer (NSCLCa) results in suboptimal outcomes with a high rate of local failure and poor overall survival. We hypothesize that dose escalation using stereotactic body radiotherapy (SBRT) boost could improve upon these results. We present here a study evaluating the dosimetric feasibility of such an approach. METHODS An...

متن کامل

A comprehensive dosimetric study on switching from a Type-B to a Type-C dose algorithm for modern lung SBRT

BACKGROUND Type-C dose algorithms provide more accurate dosimetry for lung SBRT treatment planning. However, because current dosimetric protocols were developed based on conventional algorithms, its applicability for the new generation algorithms needs to be determined. Previous studies on this issue used small sample sizes and reached discordant conclusions. Our study assessed dose calculation...

متن کامل

Evaluation of Acuros XB algorithm based on RTOG 0813 dosimetric criteria for SBRT lung treatment with RapidArc

The Radiation Therapy Oncology Group (RTOG) 0813 protocol requires the use of dose calculation algorithms with tissue heterogeneity corrections to compute dose on stereotactic body radiation therapy (SBRT) non-small cell lung cancer (NSCLC) plans. A new photon dose calculation algorithm called Acuros XB (AXB) has recently been implemented in the Eclipse treatment planning system (TPS). The main...

متن کامل

Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy

BACKGROUND The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on t...

متن کامل

SU-E-T-648: Comparison of VMAT Vs Arc Treatment Plans for Patients Undergoing SBRT of Early-Stage Non-Small Cell Lung Cancer (NSCLC).

PURPOSE To evaluate the dosimetric implications of using VMAT (Volume Modulated Arc Therapy) treatment planning techniques compared to traditional Arc therapy methods for patients undergoing SBRT (Stereotactic Body Radiation Therapy) for early-stage Non-Small Cell Lung Cancer (NSCLC). METHODS Ten NSCLC cancer patients are planned with both VMAT and Arc techniques. The SBRT treatment plans com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part13  شماره 

صفحات  -

تاریخ انتشار 2012