Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.

نویسندگان

  • G N Bowers
  • C Brassard
  • S F Sena
چکیده

This article reviews key advances in ion-selective electrode technology that have made potentiometric measurements of ionized calcium (Ca2+) reliable and precise. Our use of two second-generation Ca2+ analyzers (Radiometer ICA1 and NOVA 8) made possible uninterrupted service as volume increased to 31 640 patient tests in 1985. The lower results on the NOVA 8 were adjusted upwards to match those of the ICA1 to give identical results. Both analyzers were evaluated under working conditions of high volumes and multiple operators to establish downtime, electrode life, and costs. We have classified all Ca2+ analyzers into first-, intermediate-, and second-generation instruments, the better to understand their differences. Results for large numbers of patients' sera were shown to be systematically different when any two analyzers were compared. These differences are the consequence of each manufacturer's unique choices of the following: (a) the matrix of the calcium calibration solutions, (b) the type and configuration of the reference electrode, and (c) the salt-bridge solution. Elimination of each analyzer's biases will require agreement on a reference system that defines the accuracy of Ca2+ measurements on serum, plasma, or whole blood. The sound analytical performance of today's second-generation Ca2+ analyzers has allowed us to exploit the inherent superiority of Ca2+ over total calcium (CaT) measurements in the daily care of patients. We report on the preference of Ca2+ over CaT by physicians at our hospital since the introduction of second-generation Ca2+ analyzers. Therefore, we state unequivocally from our very satisfactory experience over the past five years that Ca2+ is a clinical laboratory test whose time has come!

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pierre Wallemacq Michel Jadoul

1. Froissart M, Houillier P. Limitations of noncorrected and albumincorrected total calcium concentrations in CKD patients. Nephrol Dial Transplant 2009; 24: 2291–2292 2. Gauci C, Moranne O, Fouqueray B et al. Pitfalls of measuring total blood calcium in patients with CKD. J Am Soc Nephrol 2008; 19: 1592–1598 3. Labriola L, Wallemacq P, Gulbis B et al. The impact of the assay for measuring albu...

متن کامل

A readily available source of serum for use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes

A readily available source of serum ft r use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes A simple method for preparing human serum for use as a precision quality-control for ionized calcium using an ion-selective electrode has been described earlier [1-1. Human citrate dextrose plasma is readily available from outdated whole blood from blo...

متن کامل

Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.

We assessed the magnitude of the errors in ionized-calcium measurements resulting from changes in electrolyte composition for three different ion-selective electrodes: the Orion Model 93-20, the Radiometer F2112, and the Simon neutral carrier membrane electrode. We attempted to distinguish between errors arising from changes in calcium ion activity and those due to interferences in the electrod...

متن کامل

Ionized calcium: its significance and clinical usefulness.

Maintenance of normal blood levels of ionized calcium (Ca2+) plays an important role in the management of the critically ill patient. Therefore, Ca2+ should be collected properly and measured reliably. The sound analytical performance of today's Ca2+ analyzers using ion-selective electrode technology have made measurements accurate and precise. The introduction of this technology allows rapid a...

متن کامل

Linearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes.

We studied the stability and linearity of the AVL and Nova Mg and Ca ion-selective electrodes and the relation between the ionized Ca and ionized Mg results reported by each analyzer. The response of the electrodes to different concentrations of Mg and Ca was determined for saline solutions, aqueous solutions, and serum samples. The electrodes from both manufacturers demonstrated acceptable sta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 1986