First clinical case of boron neutron capture therapy for head and neck malignancies using 18F-BPA PET.

نویسندگان

  • Teruhito Aihara
  • Junichi Hiratsuka
  • Norimasa Morita
  • Masako Uno
  • Yoshinori Sakurai
  • Akira Maruhashi
  • Koji Ono
  • Tamotsu Harada
چکیده

BACKGROUND We investigated the application of boron neutron capture therapy (BNCT) to suitable cancers other than glioblastoma and melanoma. Head and neck malignancies were consequently selected as adaptable cancers. We reported the clinical results of our first case treated and discussed several advantages to the application of BNCT to head and neck tumors. METHODS The patient was a 48-year-old woman with recurrent submandibular gland cancer. We confirmed the p-boronophenylalanine (BPA)-accumulating capacity of the tumor by fluorine-18-labeled p-boronophenylalanine positron emission tomography ((18)F-BPA PET) before BNCT. The tumor/normal tissue boron concentration ratio was 2.9. The patient underwent a preirradiation CT scan for treatment planning performed using the "SERA" software program. The tumor was irradiated at the Kyoto University Research Reactor with epithermal neutrons 5 MW for 90 minutes. The tumor dose and normal tissue dose calculated ranged from 20.0 to 25.2 Gy and from 3.2 to 5.8 Gy, respectively. RESULTS To date there has been continuous complete regression in the tumor and no acute and chronic complications for 1.5 years. CONCLUSIONS Although only 1 patient has shown complete regression and additional long-term follow-up should be required to assess this treatment, we believe that head and neck tumors are suitable for BNCT and that such excellent results will have a great impact on patients in the near future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic changes in 18F-borono-L-phenylalanine uptake in unresectable, advanced, or recurrent squamous cell carcinoma of the head and neck and malignant melanoma during boron neutron capture therapy patient selection

BACKGROUND We evaluated dynamic changes in 18F-borono-L-phenylalanine (18F-BPA) uptake in unresectable, advanced, or recurrent squamous cell carcinoma of the head and neck (SCC) and malignant melanoma (MM) during boron neutron capture therapy (BNCT) patient selection. METHODS Dynamic changes in the maximum standardized uptake value (SUVmax), tumor-to-normal tissue ratio (TNR), and tumor-to-bl...

متن کامل

Relationship between the uptake of 18F-borono-L-phenylalanine and L-[methyl-11C] methionine in head and neck tumors and normal organs

BACKGROUND AND PURPOSE The purpose of this study was to determine the distribution of 4-borono-2-18F-fluoro-phenylalanine (18F-BPA) and L-[methyl-11C] methionine (11C-Met) in normal organs and tumors and to evaluate the usefulness of 11C-Met/PET in screening potential candidates for boron neutron capture therapy (BNCT). MATERIAL METHODS Seven patients who had at least one histologically confi...

متن کامل

Optimum neutron energy simulation in treatment of head and neck cancer at different depths in the BNCT method

Introduction: Recently head and neck cancer has pay attention to many researchers. Its therapeutic methods include surgery, chemotherapy, radiotherapy and Boron neutron capture therapy (BNCT). BNCT is better than conventional radiotherapy because it targets the tumor cell. This method involves two steps of infusion of stable 10B and then neutron radiation with a suitable intens...

متن کامل

Dosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study

Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...

متن کامل

Dosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study

Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Head & neck

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 2006