The influence of silane evaporation procedures on microtensile bond strength between a dental ceramic and a resin cement.

نویسندگان

  • Carolina Nemesio de Barros Pereira
  • Vicente Tadeu Lopes Buono
  • Joao Mauricio Lima de Figueiredo Mota
چکیده

AIM To assess the influence of silane evaporation procedures on bond strength between a dental ceramic and a chemically activated resin cement. MATERIALS AND METHODS Eighteen blocks (6 mm Chi 14 mm Chi 14 mm) of ceramic IPS Empress 2 were cemented (C and B) to composite resin (InTen-S) blocks using a chemical adhesive system (Lok). Six groups were analyzed, each with three blocks divided according to ceramic surface treatment: two control groups (no treatment, NT; 10% hydrofluoric acid plus silane Monobond-S dried at room temperature, HFS); the other four groups comprised different evaporation patterns (silane rinsed and dried at room temperature, SRT; silane rinsed in boiling water and dried as before, SBRT; silane rinsed with boiling water and heat dried at 50 degrees C, SBH; silane dried at 50 +/- 5 degrees C, rinsed in boiling water and dried at room temperature, SHBRT). The cemented blocks were sectioned to obtain specimens for microtensile test 7 days after cementation and were stored in water for 30 days prior to testing. Fracture patterns were analyzed by optical and scanning electron microscopy. Statistics and RESULTS All blocks of NT debonded during sectioning. One way ANOVA tests showed higher bond strengths for HFS than for the other groups. SBRT and SBH were statistically similar, with higher bond strengths than SRT and SHBRT. Failures were 100% adhesive in SRT and SHBRT. Cohesive failures within the "adhesive zone" were detected in HFS (30%), SBRT (24%) and SBH (40%). CONCLUSION Silane treatment enhanced bond strength in all conditions evaluated, showing best results with HF etching.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of hydrofluoric acid concentration and etching time on microtensile bond strength of suprinity and enamic CAD/CAM ceramics to resin cement

Introduction: The use of dental ceramics has increased due to their beauty and biocompatibility. The aim of this study was to evaluate the effect of hydrofluoric acid concentration and etching time on microtensile bond strength (μTBS) of the Enamic and Suprinity ceramics. Material & Methods: In this in vitro study, two hydrofluoric acid (HFA) concentrations of 5% (A) and 10% (B) were used at t...

متن کامل

Effect of the Etching Duration and Ultrasonic Cleaning on Microtensile Bond Strength Between Feldspathic Ceramic and Resin Cement

This study assessed the effect of different etching time of hydrofluoric acid and ultrasonic cleaning of the etched ceramic surface on the resin microtensile bond strength stability to a feldspathic ceramic. The research hypotheses investigated were: (1) different etching time does not affect the adhesion resistance; (2) ultrasonic cleaning improves the adhesion resistance. Forty-eight (48) blo...

متن کامل

The effect of different surface treatments on bond strength between leucite reinforced feldspathic ceramic and composite resin.

OBJECTIVES The aim of this study was to evaluate the effect of different surface treatments on the microtensile bond strength between a leucite reinforced glass-ceramic and composite resin. METHODS Leucite reinforced ceramic blocks (n=24) were constructed using the hot pressing technique. The blocks were assigned to 4 groups, which received the following surface treatments: G1: hydrofluoric (...

متن کامل

Silanization effect on microtensile bond strength of a self-adhesive luting material to a disilicate- based glass ceramic

Introduction: The rehabilitation of teeth by means of ceramic indirect restorations has been widely performed. Previous studies has shown the effectiveness of silane coupling agents on improving the bond strength of the adhesion of resin cements to ceramics; however, some studies question the use of silane. Objective: To evaluate the effect of silane application on the microtensile bond strengt...

متن کامل

Evaluation of microtensile bond strength of repaired dental resin composite using different surface treatment techniques: A laboratory study

Background and Aims: Today, resin composites are one of the most commonly used materials in restorative dentistry. However, failure in resin treatments is also common due to its chemical nature and its high talent for decay recurrence. According to conservative approaches, "conservative" treatments are more likely to be considered than "Replacement" of damaged remedies. The purpose of this stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian journal of dental research : official publication of Indian Society for Dental Research

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2010