Validation of a new non-invasive blood pressure measurement method on mice via pulse wave propagation time measurement on a cuff.

نویسندگان

  • Xuan P Nguyen
  • Ralf Kronemayer
  • Peter Herrmann
  • Atila Mejía
  • Zamira Daw
  • Xuan D Nguyen
  • Bettina Kränzlin
  • Norbert Gretz
چکیده

In the present article, we describe the validation of a new non-invasive method for measuring blood pressure (BP) which also enables to determine the three BP values: systolic, diastolic and mean value. Our method is based on the pulse transit time (PTT) measurement along an artery directly at the BP cuff. The accuracy of this method was evaluated by comparison with the direct simultaneous measurement of blood pressure from 40 anesthetized female mice. Close correlation between the gained data from these two methods was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken...

متن کامل

Non Invasive Estimation of blood pressure using a linear regression model from the photoplethysmogram (PPG) Signal

Nowadays most of the blood pressure measuring devices rely on a common concept of inflatable cuff to the arm which is based on auscultatory or oscillometry principle. These existing blood pressure meters, based on cuff are considered to be inconvenient for daily monitoring and these are very sensitive to artefacts due to the presence of cuff. The other non invasive methods like PTT, PAT require...

متن کامل

New Ways of Non-invasive Measuring of Blood Circulation Parameters

The purpose of the article is to describe possible ways of non-invasive measuring and analysis of blood circulation parameters. These parameters are very important indicators of various cardiovascular diseases in clinical practice. For this purpose, methods of purely non-invasive analysis are sought. A standard approach is to use an inflatable cuff for blood pressure monitoring and analysis, us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedizinische Technik. Biomedical engineering

دوره 56 3  شماره 

صفحات  -

تاریخ انتشار 2011