Ground Reaction Force Estimates from ActiGraph GT3X+ Hip Accelerations
نویسندگان
چکیده
Simple methods to quantify ground reaction forces (GRFs) outside a laboratory setting are needed to understand daily loading sustained by the body. Here, we present methods to estimate peak vertical GRF (pGRFvert) and peak braking GRF (pGRFbrake) in adults using raw hip activity monitor (AM) acceleration data. The purpose of this study was to develop a statistically based model to estimate pGRFvert and pGRFbrake during walking and running from ActiGraph GT3X+ AM acceleration data. 19 males and 20 females (age 21.2 ± 1.3 years, height 1.73 ± 0.12 m, mass 67.6 ± 11.5 kg) wore an ActiGraph GT3X+ AM over their right hip. Six walking and six running trials (0.95-2.19 and 2.20-4.10 m/s, respectively) were completed. Average of the peak vertical and anterior/posterior AM acceleration (ACCvert and ACCbrake, respectively) and pGRFvert and pGRFbrake during the stance phase of gait were determined. Thirty randomly selected subjects served as the training dataset to develop generalized equations to predict pGRFvert and pGRFbrake. Using a holdout approach, the remaining 9 subjects were used to test the accuracy of the models. Generalized equations to predict pGRFvert and pGRFbrake included ACCvert and ACCbrake, respectively, mass, type of locomotion (walk or run), and type of locomotion acceleration interaction. The average absolute percent differences between actual and predicted pGRFvert and pGRFbrake were 8.3% and 17.8%, respectively, when the models were applied to the test dataset. Repeated measures generalized regression equations were developed to predict pGRFvert and pGRFbrake from ActiGraph GT3X+ AM acceleration for young adults walking and running. These equations provide a means to estimate GRFs without a force plate.
منابع مشابه
Accelerometer counts and raw acceleration output in relation to mechanical loading.
The purpose of this study was to assess the relationship of accelerometer output, in counts (ActiGraph GT1M) and as raw accelerations (ActiGraph GT3X+ and GENEA), with ground reaction force (GRF) in adults. Ten participants (age: 29.4 ± 8.2 yr, mass: 74.3 ± 9.8 kg, height: 1.76 ± 0.09 m) performed eight trials each of: slow walking, brisk walking, slow running, faster running and box drops. GRF...
متن کاملBiomechanical examination of the 'plateau phenomenon' in ActiGraph vertical activity counts.
This paper determines if the leveling off ('plateau/inverted-U' phenomenon) of vertical ActiGraph activity counts during running at higher speeds is attributable to the monitor's signal filtering and acceleration detection characteristics. Ten endurance-trained male participants (mean (SD) age = 28.2 (4.7) years) walked at 3, 5 and 7 km h(-1), and ran at 8, 10, 12, 14, 16, 18 and 20 km h(-1) on...
متن کاملReliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions
BACKGROUND Reliability of the Actigraph GT3X+ accelerometer has not been determined under normal wear time criteria in a large sample of subjects and accelerometer units. The aim of this study was to assess contralateral hip difference and inter-instrument reliability of the Actigraph GT3X+ monitor in adults under long-term free-living conditions. METHODS Eighty-seven adult subjects (28 men; ...
متن کاملTranslation equations to compare ActiGraph GT3X and Actical accelerometers activity counts
BACKGROUND This study aimed to develop a translation equation to enable comparison between Actical and ActiGraph GT3X accelerometer counts recorded minute by minute. METHODS Five males and five females of variable height, weight, body mass index and age participated in this investigation. Participants simultaneously wore an Actical and an ActiGraph accelerometer for two days. Conversion algor...
متن کاملValidation of Five Minimally Obstructive Methods to Estimate Physical Activity Energy Expenditure in Young Adults in Semi-Standardized Settings
We compared the accuracy of five objective methods, including two newly developed methods combining accelerometry and activity type recognition (Acti4), against indirect calorimetry, to estimate total energy expenditure (EE) of different activities in semi-standardized settings. Fourteen participants performed a standardized and semi-standardized protocol including seven daily life activity typ...
متن کامل