Multifractality, sample entropy, and wavelet analyses for age-related changes in the peripheral cardiovascular system: preliminary results.

نویسندگان

  • Anne Humeau
  • François Chapeau-Blondeau
  • David Rousseau
  • Pascal Rousseau
  • Wojciech Trzepizur
  • Pierre Abraham
چکیده

Using signal processing measures we evaluate the effect of aging on the peripheral cardiovascular system. Laser Doppler flowmetry (LDF) signals, reflecting the microvascular perfusion, are recorded on the forearm of 27 healthy subjects between 20-30, 40-50, or 60-70 years old. Wavelet-based representations, Hölder exponents, and sample entropy values are computed for each time series. The results indicate a possible modification of the peripheral cardiovascular system with aging. Thus, the endothelial-related metabolic activity decreases, but not significantly, with aging. Furthermore, LDF signals are more monofractal for elderly subjects than for young people for whom LDF signals are weakly multifractal: the average range of Holder exponents computed with a parametric generalized quadratic variation based estimation method is 0.13 for subjects between 20 and 30 years old and 0.06 for subjects between 60 and 70 years old. Moreover, the average mean sample entropy value of LDF signals slightly decreases with age: it is 1.34 for subjects between 20 and 30 years old and 1.19 for subjects between 60 and 70 years old. Our results could assist in gaining knowledge on the relationship between microvascular system status and age and could also lead to a more accurate age-related nonlinear modeling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic age-related changes of extracellular field potential of isolated AV-node of rabbit

Introduction: Developmental changes in atrioventricular nodal conduction time and refractoriness have been shown in several studies. Prevalence of atrioventricular nodal reentrant tachycardia (AVNRT) is clearly age-dependent. The purpose of this study was to determine developmental changes of basic and frequency-dependent electrophysiological properties of the atrioventricular node (AV-node)...

متن کامل

غربالگری آترواسکلروز با روش اندکس پایی - بازویی در بیماران دیابتی نوع 2 و ارتباط آن با سایر عوامل

Background & Aims: Diabetes mellitus, as the most common metabolic disorder in the world with increasing incidence, is associated with advanced atherosclerotic changes in cardiac, cerebral and peripheral vasculature.  Atherosclerosis by making some changes is related to the cardiac and cerebral vasculature.   Establishment of peripheral vascular complication leads to early diagnosis, prevention...

متن کامل

Fault diagnosis of gearboxes using LSSVM and WPT

This paper concentrates on a new procedure which experimentally recognises gears and bearings faults of a typical gearbox system using a least square support vector machine (LSSVM). Two wavelet selection criteria Maximum Energy to Shannon Entropy ratio and Maximum Relative Wavelet Energy are used and compared to select an appropriate wavelet for feature extraction. The fault diagnosis method co...

متن کامل

Detecting pitting corrosion and its severity using wavelet entropy in electrochemical noise measurement

Entropy as a measure of uncertainty was used to represent the results of the wavelet technique in electrochemical noise analysis. The experimental signals were obtained by recording the electrochemical potential and current noise of 7075 aluminum alloy in 3.5% NaCl solution. The electrochemical potential and current noise were decomposed into 16 levels using Daubechies wavelets. Wavelet output ...

متن کامل

Studying Influence of Preheating Conditions on Design Parameters of Continuous Paint Cure Ovens

This paper concentrates on a new procedure which experimentally recognises gears and bearings faults of a typical gearbox system using a least square support vector machine (LSSVM). Two wavelet selection criteria Maximum Energy to Shannon Entropy ratio and Maximum Relative Wavelet Energy are used and compared to select an appropriate wavelet for feature extraction. The fault diagnosis method co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2008