Classification of eccentric fixation.

نویسندگان

  • S R Malik
  • A K Gupta
  • S Choudhry
چکیده

The literature on eccentric fixation includes numerous systems of classification devised by different workers. At the orthoptic and pleoptic centre at this hospital, we have tried to use some of these classifications, but have observed certain discrepancies which are discussed below. Some classifications are based on anatomical landmarks (Mayweg and Massie, 1958; von Noorden, 1959; Scully and Naylor, I96I; von Noorden and Lipsius, I964) and others on the relationship of the fovea with the fixation target (Byron, I960; Agarwal, Khosla, and Angra, I964). Table I (opposite) shows much disparity in nomenclature. The same degree ofeccentric fixation has been differently described by different workers: e.g. 30 eccentric fixation was included under paramacular fixation by Byron (I960) but under parafoveal fixation by Agarwal and others (I964). Similarly, 5' eccentric fixation was termed "centrocaecal" by Byron (I960) and "paramacular" by Agarwal and others (I964).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trial with red filter in the treatment of eccentric fixation.

FOLLOWING the preliminary reports of Brinker and Katz (1963) and Binder, Engel, Ede, and Loon (1963) on the possible use of a red filter in the management of eccentric fixation, we tried this method of treatment in a series of eighteen cases, ten of which completed the investigation. Six of these were cases of eccentric fixation of the paramacular type, two of the parafoveal type, and two were ...

متن کامل

Comparison of eccentric fixation measurements using the streak target of an ophthalmoscope and a traditional visuoscopy target.

PURPOSE To compare measurements of eccentric fixation using two different targets for fixation, a traditional visuoscope target and the streak target of an ophthalmoscope. PATIENTS AND METHODS Monocular fixation was evaluated using visuoscopy in 47 patients ranging in age from 4 months to 22 years. Visuoscopy measurements were compared using both the traditional visuoscope target and the stre...

متن کامل

Effect of eccentric and inconsistent fixation on retinal optical coherence tomography measures.

OBJECTIVE To assess the relative stabilities of optical coherence tomography (OCT)-based retinal volume and central foveal thickness measurements in the setting of eccentric or inconsistent fixation. METHODS Ten healthy right eyes underwent multiple macular OCT centered at fixation. To model the effect of eccentric or inconsistent fixation, OCT was repeated with scan centers precisely shifted...

متن کامل

On the relationship between strabismic amblyopia and eccentric fixation.

Landolt C and grating acuity are compared with that normally expected of the eccentric fixation region for 10 strabismic amblyopes. The findings suggest that 2 populations of amblyopes exist. For some amblyopes visual function is that predicted of the eccentric region used for fixation, whereas for other amblyopes there is a further pathological reduction in visual function. These findings may ...

متن کامل

Treatment of eccentric fixation by the use of a red filter.

THE treatment of amblyopia and eccentric fixation is said to be associated with special problems. In some centres pleoptics have been used, but the need for trained staff and special equipment can pose difficult problems. The harmful effects of conventional occlusion of the fixing eye have been stressed by Arruga (1962). Recently, Brinker and Katz (1963) have drawn attention to the fact that, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 53 3  شماره 

صفحات  -

تاریخ انتشار 1969