A quantitative analysis of left ventricular myocardial function in the intact, sedated dog.

نویسندگان

  • R R Taylor
  • J Ross
  • J W Covell
  • E H Sonnenblick
چکیده

Instantaneous contractile element velocity was calculated from left ventricular pressure and its first derivative during isovolumic left ventricular contractions produced by sudden balloon occlusion of the ascending aorta during diastole in closed-chest, sedated dogs. Wall tension was derived from ventricular pressure and volume, the latter being obtained from the pressure-volume relation of the arrested ventricle. During isovolumic contractions, there was an inverse curvilinear relation between tension and velocity, except at the onset of contraction and near peak tension. Increasing diastolic ventricular volume shifted the tension-velocity relations to the right, with increase in mean total isovolumic tension from 188 to 471 g/cm, but without an obvious change in extrapolation to maximum velocity, which averaged 3.0 circumferences/sec. End-diastolic pressure-tension and circumference-tension relations indicated that active tension development continued to increase up to the maximum measured enddiastolic pressures of approximately 20 mm Hg. The normalized data, pooled from 15 animals, showed little scatter in the data for tension and velocity. It is concluded that the contractile properties of left ventricular muscle in the intact, sedated dog may be meaningfully described by tension-velocity relations obtained from single isovolumic contractions. The responses of the intact ventricle to increased diastolic volume and digitalis glycosides are analogous to those of isolated cardiac muscle. The small variability in the normalized tension-velocity relations in the normal dog suggests that it will also be possible to characterize abnormal left ventricular function with this approach. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

Measurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images

Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...

متن کامل

Effect of exercise training and L-arginine supplementation on oxidative stress and left ventricular function in rats with myocardial infarction

Introduction: The aim of the present study was to evaluate the effect of exercise training and L-arginine supplementation on oxidative stress and systolic ventricular function in rats with myocardial infarction (MI). Methods: Four weeks after the surgically-induced MI, 40 male Wistar rats were randomly assigned to the following 4 groups (n=10): MI-sedentary control (Sed) MI-exercise (Ex) MI-...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 1967