One-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent
نویسندگان
چکیده
Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were prospectively randomized to the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or an identical-appearing bare-metal EXPRESS stent. By actuarial analysis, the TAXUS stent compared with the bare-metal stent reduced the 12-month rates of target-lesion revascularization by 73% (4.4% versus 15.1%, P 0.0001), target-vessel revascularization by 62% (7.1% versus 17.1%, P 0.0001), target-vessel failure by 52% (10.0% versus 19.4%, P 0.0001), and composite major adverse cardiac events by 49% (10.8% versus 20.0%, P 0.0001). The 1-year rates of cardiac death (1.4% versus 1.3%), myocardial infarction (3.5% versus 4.7%), and subacute thrombosis (0.6% versus 0.8%) were similar between the paclitaxel-eluting and control stents, respectively. Between 9 and 12 months, there were significantly fewer myocardial infarctions (0% versus 1.1%, P 0.007), target-vessel revascularizations (2.4% versus 5.8%, P 0.002), and major adverse cardiac events (2.4% versus 6.3%, P 0.0009) in the paclitaxel-eluting stent than in the control stent group, respectively. Conclusions—The relative efficacy reported at 9 months for the polymer-based, paclitaxel-eluting TAXUS stent compared with the EXPRESS stent is preserved and continues to increase at 1 year, with no safety concerns apparent. (Circulation. 2004;109:1942-1947.)
منابع مشابه
One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent in patients with diabetes mellitus.
Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...
متن کاملOne-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial.
BACKGROUND The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. METHODS AND RESULTS In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were ...
متن کاملOutcomes of paclitaxel-eluting stent implantation in patients with stenosis of the left anterior descending coronary artery.
OBJECTIVES We sought to examine the efficacy of paclitaxel-eluting stent implantation in the left anterior descending coronary artery (LAD). BACKGROUND Restenosis and recurrent cardiac events after percutaneous intervention are more common for lesions in the LAD than other native coronary arteries, and often necessitate bypass surgery. Drug-eluting stents may improve the long-term prognosis o...
متن کاملFinal 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions.
BACKGROUND The TAXUS II trial was designed to evaluate the safety and efficacy of the commercialized slow-release (SR) and an investigation-only moderate-release (MR) polymer-based TAXUS paclitaxel-eluting stent compared with a bare-metal stent for the treatment of de novo coronary lesions. METHODS AND RESULTS This prospective, randomized, double-blind, controlled trial enrolled 536 patients ...
متن کاملTAXUS VI 2-year follow-up: randomized comparison of polymer-based paclitaxel-eluting with bare metal stents for treatment of long, complex lesions.
AIMS Drug-eluting stents (DESs) have shown to be effective in reducing in-stent restenosis, although data relating to long-term experience in treating more complex lesion subsets are limited. In order to assess the long-term safety and clinical efficacy of the polymer-based moderate release (MR) paclitaxel-eluting TAXUS MR stent in treatment of complex lesion subsets, we evaluated the 2-year fo...
متن کامل