Systematic Review of Defibrillation Threshold Testing at De Novo Implantation.
نویسندگان
چکیده
BACKGROUND Recent results from the largest multicenter randomized trial (Shockless IMPLant Evaluation [SIMPLE]) on defibrillation threshold (DFT) testing suggest that while shock testing seems safe, it does not reduce the risk of failed shocks or prolong survival. A contemporary systematic review of DFT versus no-DFT testing at the time of implantable cardioverter-defibrillator implantation was performed to evaluate the current evidence and to assess the impact of the SIMPLE study. METHODS AND RESULTS Electronic searches were performed using 6 databases from their inception to March 2014. Relevant studies investigating implant DFT were identified. Data were extracted and analyzed according to predefined clinical end points. Predefined outcomes for interrogation were all-cause mortality, composite end point of implantable cardioverter-defibrillator efficacy (arrhythmic deaths and ineffective shocks), and composite safety end point (the sum of complications recorded at 30 days). Meta-analysis was performed including 13 studies and 9740 patients. No significant differences between DFT versus no-DFT cohorts were found in terms of all-cause mortality (risk ratio, 0.90; 95% confidence interval, 0.71-1.15; P=0.41), composite efficacy outcome (risk ratio, 1.24; 95% confidence interval, 0.65-3.37; P=0.51), and 30-day postimplant complications (risk ratio, 1.18; 95% confidence interval, 0.87-1.60; P=0.29). No significant difference was found in the trends observed when the results of the SIMPLE study were excluded or included. CONCLUSIONS This systematic review of contemporary data suggests a modest average effect of DFT, if any, in terms of mortality, shock efficacy, or safety. Therefore, DFT testing should no longer be compulsory during de novo implantation. However, DFT testing may still be clinically relevant in specific patient populations.
منابع مشابه
Shoulder Joint Dislocation as an Unusual Complication of Defibrillation Threshold Testing Following Subcutaneous Implantable Cardioverter-Defibrillator Implantation
A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e. palm up) and strapped to the arm extender. The generator was placed in the left mid-axillary line along the 5th-6th intercostal spaces and the defibrillation coil was tunneled anterior to the sternum. Defibrillation thr...
متن کاملComparison of outcomes in patients undergoing defibrillation threshold testing at the time of implantable cardioverter-defibrillator implantation versus no defibrillation threshold testing.
BACKGROUND Inability to perform defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantation due to co-morbidities may influence long-term survival. METHODS Retrospective review at The University of Michigan (1999-2004) identified 55 patients undergoing ICD implantation without DFT testing ("No-DFT group"). A randomly selected sample of patients (n =...
متن کاملDefibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.
BACKGROUND The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought...
متن کاملDefibrillation testing: should the paradigm shift?
In 3 decades of clinical use of the implantable cardioverter-defibrillator (ICD), defibrillation threshold (DFT) testing has remained an integral part of the implantation procedure. The prevailing rationale for the routine evaluation of DFTs has been to ensure appropriate sensing of ventricular fibril-lation, system integrity, and effective defibrillation (1–3). Early ICD systems using monophas...
متن کاملA prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.
Biphasic waveforms have been suggested as a superior waveform for ventricular defibrillation. To test this premise, a prospective randomized intraoperative evaluation of defibrillation efficacy of monophasic and biphasic waveform pulses was performed in 22 survivors of out of hospital ventricular fibrillation who were undergoing cardiac surgery for implantation of an automatic defibrillator. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2016