[Comparison of recovery time in a cold provocation test performed according to Polish requirements and ISO 14835-1 standard].

نویسنده

  • Barbara Harazin
چکیده

BACKGROUND A cold provocation test is used to assess the presence and extent of the peripheral vascular disorders in the upper extremities of workers exposed to hand-arm vibration. A quantitative evaluation of vascular response to cold provocation is determined by measuring the finger skin temperature. In the study two methods of cold exposure were used to assess the effect of water temperature and immersion duration on recovery time in subjects with the acropoikilothermic thermoregulation. MATERIAL AND METHODS In the study two cold provocation tests were performed. One test consisted of a 10 min immersion of both hands in cold water at 14 degrees C (Polish requirements) and the second one adequately, of a 5 min immersion in cold water at 12 degrees C (ISO 14835-1:2004 standard). Twenty young (aged 22-24 years) and healthy subjects took part in each test. Finger skin temperature was measured on all fingers of both hands before and after immersion. RESULTS The mean recovery time of the cold provocation test was longer in the group examined by ISO 14835-1:2004 standard requirements than in the group examined by the method used in Poland. CONCLUSIONS Immersion parameters used in the cold provocation test performed in acropoikilotherms have a significant effect on recovery time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of finger systolic blood pressure (FSBP) cooling tests.

A finger systolic blood pressure (FSBP) cooling test was introduced in 1977 and standardized during the following years for the optimal provocation and best characterization of an attack of vasospastic Raynaud's phenomenon (RP). The purpose of the present review is to compare and analyse some different techniques used in FSBP cooling tests from different countries and described in the final dra...

متن کامل

Proposing a quantitative approach to measure the success of energy management systems in accordance with ISO 50001: 2011 using an analytical hierarchy process (AHP)

ISO 50001: 2011 provides an integrated and systematic framework to plan, implement, operate, certify, and maintain energy management systems (EMSs). Evaluation of organizations in relation to meeting the standard requirements is performed by an auditing qualitative approach. In this research, a quantitative approach has been proposed and implemented to assess organizations and rank them based o...

متن کامل

Comparison of a local made temporary cement (P-cem), with an imported brand (Temp Bond) using ISO 3107 criteria

Comparison of a local made temporary cement (P-cem), with an imported brand (Temp Bond) using ISO 3107 criteria Dr. Fallahi, M.R.* - Dr. Bayan Zadeh, S.M.** - Dr. Malkomian, L.*** *Dentist. **Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Tehran University / Medical Sciences. ***Statistician. Abstract Background & Aim: The local made eugenol-free temporary cement (P-cem) has...

متن کامل

Evaluation of various characteristics of Plastalgin alginate according to International ISO Standards and ADA specifications

Evaluation of various characteristics of Plastalgin alginate according to International ISO Standards and ADA specifications Dr. A. Monzavi* - Dr. GH. Omati Shabestari** - Dr. S. Shahabi*** - Dr. F. Hajloo**** *- Associate Professor of Removable Prosthodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Removable Prosthodontics Dept. Faculty ...

متن کامل

DI AGNOSTIC VAL UE OF SUBL INGUAL NITROGLYCERIN TILT TEST: COMPARISON WITH THE STANDARD ISOPROTERENOL TILT TEST

Sublingual nitroglycerin (TNG) has been introduced as a promising provocative agent for tilt table testing, but it has not been compared directly with the standard isoproterenol (ISO) infusion test previously. We tried to assess the diagnostic value and safety of TNG tilt testing as compared with ISO infusion in patients with unexplained syncope. TNG and ISO tilt tests were performed in tw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medycyna pracy

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2010