Endograft connector technique to treat popliteal artery aneurysm in a morbid obese patient.
نویسندگان
چکیده
Surgical repair of popliteal artery aneurysm in morbid obese patients poses additional challenges. We report a morbid obese patient who had a 59 mm right popliteal artery aneurysm which was successfully treated with the endograft connector technique. This technique was used to perform the distal anastomosis of the below-knee femoro-popliteal bypass. A 10 mm Dacron graft was used as a main graft bypass and an 11 mm/10 cm stentgraft as endograft connector. Following the respective tunnel of the Dacron graft, an end-to-side proximal anastomosis was performed at distal femoral artery. The aneurysm exclusion was obtained through a proximal and a distal ligation. Postoperative duplex showed adequate bypass patency. Knee x-rays demonstrated no signs of stent kinking/fractures. The postoperative course was uneventful and the patient was discharged home on fourth day post operative. The six-month computed tomography scan and the 12-month duplex control showed a patent bypass with no signs of stenosis.
منابع مشابه
Endovascular Repair of Ruptured Popliteal Artery Aneurysms: A Case Report and Review of the Literature
OBJECTIVE/BACKGROUND The objectives were to report the management and outcomes of a 96-year-old man who presented with an acutely swollen right leg due to a ruptured popliteal aneurysm, and to review the relevant literature. METHODS A ruptured popliteal artery aneurysm is a rare diagnosis and is one that is often missed at time of presentation. Previous case reports have documented successful...
متن کاملExternalized Guidewires to Facilitate Fenestrated Endograft Deployment in the Aortic Arch
PURPOSE To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. TECHNIQUE For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated w...
متن کاملManagement of ectatic, nonaneurysmal iliac arteries during endoluminal aortic aneurysm repair.
PURPOSE Most endografts for an endoluminal AAA repair cannot achieve an adequate hemostatic seal in ectatic common iliac arteries larger than 14 mm. The extension of the endograft into the external iliac artery can alleviate this problem but requires sacrifice of the internal iliac artery. We have used the larger diameter aortic extension cuff to obtain adequate endograft to arterial wall appos...
متن کاملSuccessful use of retrograde branched extension limb assembling technique in endovascular repair of pararenal abdominal aortic aneurysm
Surgeon-modified retrograde branched extension limb assembling technique and bridged endografts were successfully used to exclude an asymptomatic pararenal abdominal aortic aneurysm and to reconstruct the superior mesenteric artery and bilateral renal arteries in a case with high-grade celiac artery stenosis, nondilated aorta above the superior mesenteric artery, and large lumen below the renal...
متن کاملEmergent endovascular repair of a ruptured giant internal iliac artery aneurysm using an inverted iliac limb endograft
An 88-year-old man with hypertension, coronary artery disease, morbid obesity, and a remote history of a prior open abdominal aortic aneurysm repair with an infrarenal tube graft developed acute abdominal pain accompanied by dizziness after a bowel movement. He was taken to an outside hospital, where a computed tomography angiogramwas obtained. This demonstrated a right internal iliac artery an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vascular
دوره 23 2 شماره
صفحات -
تاریخ انتشار 2015