Human prolactin: measurement in plasma by in vitro bioassay.

نویسندگان

  • D L Kleinberg
  • A G Frantz
چکیده

Prolactin has been measured in unextracted human plasma by a sensitive and specific in vitro bioassay. Secretory activity of breast tissue fragments from mid-pregnant mice, incubated in organ culture with human plasma, serves as the histologic end point. Sensitivity is 5 ng/ml (0.14 mU/ml) or somewhat better for ovine prolactin, and approximately 0.42 mU/ml for prolactin activity of human plasma at the dilutions used in the assay. Human growth hormone as it circulates in blood, like the material extracted from pituitary glands, is strongly lactogenic. Antisera to human growth hormone are capable of completely neutralizing the prolactin effect of large amounts (600 ng/ml) of human growth hormone added to the system. Plasma prolactin activity is less than 0.42 mU/ml in normal men and women. Of 26 patients with nonpuerperal galactorrhea, 14 had elevated prolactin activities ranging from 0.42 to 3.5 mU/ml. Growth hormone levels by radioimmunoassay were far too low, in general, to account for the observed prolactin activity. All of 14 nursing mothers, 1-30 days post partum, had elevated prolactin activity with a mean of 2.29 and a total range of 0.56-4.5 mU/ml. Growth hormone was in the low normal range in all of these subjects. Seven patients on psychoactive drugs of the phenothiazine series similarly had elevated prolactin activity with low growth hormone. Antiserum to human growth hormone, when preincubated with plasma samples from each of these three groups of subjects, produced no significant inhibition of prolactin activity. In two acromegalic patients with markedly elevated growth hormone levels, antiserum to growth hormone produced complete inhibition of prolactin activity in one and partial inhibition in the other. These studies indicate that human growth hormone and human prolactin are separate molecules, with little if any immunologic cross-reactivity, at least as demonstrated by the antisera used in this study, and that their release is governed by different physiologic mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Effect of pheromones on the plasma level of prolactin during pregnancy and lactating periods in female rat

Introduction: Pheromones play a great role in the reproductive and social behavior of animals. The main sources of pheromones are urine and paracrine secretions. Through the neuroendocrine system, prolactin is a safe parameter to measure and compare the effects of pheromones on the sexual, maternal and also lactating behavior. Methods: Female rats were divided into 19 groups (n=8). To measur...

متن کامل

مقایسه تعیین مقدار TNF- به دو روشImmunoassay وbioassay در پلاکتهای متراکم

Background: Tumor necrosis factor alpha (TNF-) is a major mediator of inflammatory responses and also plays a role in Febrile non-hemolytic reactions (FNHRs) after platelet concentrates (PCs) injection. It is thought contaminating WBCs are the source of these cytokine so inactivating or decreasing of these WBCs will be effective to decline of the cytokines. Due to difference results between di...

متن کامل

Plasma prolactin activity in inappropriate lactation.

Using a bioassay dependent on the development of a lactogenic response in rabbit mammary tissue cultured in vitro, prolactin distinct from immunoreactive growth hormone has been found in the plasma of patients of both sexes with inappropriate lactation with and without evidence of pituitary tumours. It has also been found in one patient with primary hypothyroidism and galactorrhoea, and in anot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 1971