Midterm ‘super-response’ to cardiac resynchronization therapy by biventricular pacing with fusion: insights from electro-anatomical mapping

نویسندگان

  • Radu Vatasescu
  • Antonio Berruezo
  • Lluis Mont
  • David Tamborero
  • Marta Sitges
  • Etel Silva
  • Jose María Tolosana
  • Bárbara Vidal
  • David Andreu
  • Josep Brugada
چکیده

AIMS Some authors recommend avoiding fusion with left ventricular (LV) intrinsic depolarization during cardiac resynchronization therapy (CRT). If fusion is still present during optimized biventricular (Biv) pacing and its long-term effects on the response to CRT are currently unknown. The aim of the study was to analyse the endocardial LV activation pattern induced by echocardiographically optimized Biv pacing and its influence on LV reverse remodelling. METHODS AND RESULTS Contact electro-anatomical mapping was performed in 15 heart failure (HF) patients with left bundle branch block and echocardiographically optimized CRT (seven ischaemic aetiology, 64 +/- 8 years, three women, New York Heart Association class 3 +/- 0.4, LV ejection fraction 25 +/- 5%). Left ventricular activation maps were performed in sinus rhythm (SR), during DDD right ventricular apical (RVA) and optimized Biv pacing. Fusion with intrinsic rhythm during pacing was considered when LV septal activation was produced at least partially by intrinsic depolarization, when compared with LV activation map during SR. Patients were considered responders to CRT if they had > or =10% reduction in LV end-systolic volume (LVESV) after 6 months of CRT. During SR, the LV breakthrough was mid-septal (n = 12), basal septum (n = 2), and apical (n = 1). During RVA pacing, LV breakthrough shifted apical in all patients. Right ventricular apical/Biv pacing proved fusion with intrinsic depolarization in 8 of 15 patients. The PR interval was shorter in patients with fusion RVA/Biv pacing (164 +/- 24 vs. 234 +/- 55 ms, P = 0.006). There was a trend for shorter LV activation time (LV(at)) in patients with fusion during RVA pacing (87 +/- 33 vs. 113 +/- 21 ms, P = 0.08) as well as during optimized Biv pacing (83 +/- 18 vs. 104 +/- 24 ms, P = 0.07), although LV(at) was similar in SR (100 +/- 22 vs. 106 +/- 20, P = NS). In patients with fusion, 6 months responder rate was significantly higher (100 vs. 28.5%, P < 0.007) as was the degree of LVESV reduction (39 +/- 17 vs. 1.0 +/- 14%, P < 0.001). CONCLUSION Biventricular pacing with fusion may substantially increase the structural responder rate probably by shortening LV(at).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

lectrocardiographic imaging of cardiac resynchronization herapy in heart failure: Observation of variable lectrophysiologic responses

BACKGROUND Cardiac resynchronization therapy (CRT) for congestive heart failure patients with delayed left ventricular (LV) conduction is clinically beneficial in approximately 70% of patients. Unresolved issues include patient selection, lead placement, and efficacy of LV pacing alone. Being an electrical approach, detailed electrical information during CRT is critical to resolving these issue...

متن کامل

Delayed trans-septal activation results in comparable hemodynamic effect of left ventricular and biventricular endocardial pacing: insights from electroanatomical mapping.

BACKGROUND We sought to compare left ventricular (LVepi) and biventricular epicardial pacing (BIVepi) with LV (LVendo) and BIV endocardial pacing (BIVendo) in patients with chronic heart failure with an emphasis on the underlying electrophysiological mechanisms and hemodynamic effects. METHODS AND RESULTS Ten patients with chronically implanted cardiac resynchronization devices underwent temp...

متن کامل

Loss of continuous biventricular pacing in cardiac resynchronization therapy patients: incidence, causes, and outcomes.

INTRODUCTION AND OBJECTIVES In recent years, implantation of cardiac resynchronization therapy devices has significantly increased. The benefits of this therapy are directly related to the maintenance of continuous biventricular pacing. This study analyzed the incidence, causes, and outcomes of loss of continuous biventricular pacing, and the approach adopted. METHODS We analyzed the clinical...

متن کامل

Seeing is believing: acute haemodynamic response to predict long-term outcome in cardiac resynchronization therapy.

Many heart failure specialists still believe that the pathophysiology of cardiac resynchronization therapy (CRT) is incompletely understood; however, it must be emphasized that the main effects of biventricular pacing have already been described more than a decade ago. In 1994, Cazeau et al. reported how biventricular pacing improves clinical signs and symptoms of heart failure, acutely increas...

متن کامل

Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009