Measurement of Glomerular Filtration Rate by Rapid Intravenous Injection of a Newly Developed Inulin Fraction
نویسندگان
چکیده
OBJECTIVE Since the conventional drip-infusion method for measuring inulin clearance (Cin) has problems related to its accuracy and performance, we explored a more accurate and concise method by rapid intravenous injection of a newly developed inulin fraction (Inulead(®)), in which spot urine sampling was omitted and the administration period of inulin was shortened from 120 to 5 minutes. PATIENTS AND METHODS Twenty seven patients (M/F: 15/12, 67.8 ± 12.9 years old) admitted to the Nephrology ward were enrolled in this study. Inulead(®), 1500 mg dissolved in 150 mL of saline, was intravenously administered in 5 minutes. Then, sequential blood samplings and urine collection were performed for 24 hours. Cins were calculated by the following three formulae: (1) a pharmacokinetic analysis using a two compartments model based on the plasma inulin concentration to determine Cin, which was the administered dose divided by the area under the curve (AUC) from 0 to ∞, (2) urinary inulin excretion divided by the AUC for 24 hours and (3) the Bayesian method using a three-point set of plasma inulin concentrations to predict the change of inulin concentration to determine Cin as in 1. These Cins were compared with levels of estimated GFR (eGFR), creatinine clearance (Ccr), serum β2 microglobulin (β2MG) and serum cystatin C (Cys C). RESULTS Cins obtained by the above three methods were well correlated with each other (r. = 0.9088 (- )0.9998) and with eGFR (r. = 0.8286 - 0.8650), Ccr (r. = 0.821 - 0.864), 1/β2MG (r. = 0.631 - 0.752) and 1/CysC (r. = 0.830 - 0.857). The averaged differences of each Cin from eGFR were distributed between - 4.4 and - 4.5 mL/min. CONCLUSION Since the Cins by rapid inulin injection showed satisfactory correlation and differences with other GFR parameters, this method will be a good alternative to the drip infusion method, and may reduce the burden of patients and medical staff.
منابع مشابه
A single-injection method for measuring glomerular filtration rate.
A method for estimating glomerular filtration rate (GFR) has been developed that is based on an analysis of the total area under the plasma radioactivity-time curve after a single intravenous injection of [125I]iothalamate. Glomerular filtration rates obtained by this method (method A) and those obtained with two widely used single-injection techniques, the slope-intercept method (method B), a...
متن کاملComparison of Measurements of Glomerular Filtration Rate Using Single-injection Inulin Methods and Urinary Creatinine Clearance in Dogs with Reduced Renal Blood Flow
The purpose of this study was to evaluate the validity of the single injection of inulin (PCIn) compared with standard exogenous creatinine clearance (CCr) in dogs with renal artery stenosis. Two methods for evaluating glomerular filtration rate (GFR), after single bolus intravenous administration of inulin, were assessed in 15 dogs with renal artery stenosis to reduce blood flow ranging from 3...
متن کاملMeasurement of glomerular filtration rate by inulin clearance without urine collection.
A continuous infusion method for measuring inulin clearance (and hence glomerular filtration rate) which does not require urine collection has been re-evaluated and found to give satisfactory results. In two non-oedematous and anephric patients the plasma level of inulin became virtually constant four hours after a single intravenous dose, and hence this is the minimum time required for the inf...
متن کاملA High-throughput method for measurement of glomerular filtration rate in conscious mice.
The measurement of glomerular filtration rate (GFR) is the gold standard in kidney function assessment. Currently, investigators determine GFR by measuring the level of the endogenous biomarker creatinine or exogenously applied radioactive labeled inulin ((3)H or (14)C). Creatinine has the substantial drawback that proximal tubular secretion accounts for ~50% of total renal creatinine excretion...
متن کاملRapid method for the measurement of differential renal function: validation.
The precise measurement of glomerular filtration rate (GFR) and renal plasma flow (ERPF) usually requires continuous intravenous administration of adequate substances, with multiple blood and urine analysis, and does not allow measurement of separate renal function. Schlegel et al. and Gates described isotopic methods for the measurement of global and unilateral GFR and ERPF based on the determ...