Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses.

نویسندگان

  • Enzo Maria Vingolo
  • PierLuigi Grenga
  • Luca Iacobelli
  • Roberto Grenga
چکیده

PURPOSE To compare the visual acuity and contrast sensitivity in eyes with the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon) and eyes with the monofocal AcrySof SA60AT IOL. SETTING Policlinico Umberto I, Department of Ophthalmology, Rome, and private clinical practice, Rome, Italy. METHODS One hundred eyes had phacoemulsification cataract extraction and implantation of a ReSTOR multifocal IOL in the capsular bag. Inclusion criteria were corneal astigmatism less than 1.5 diopters (D), myopia less than 4.0 D, and no associated ocular disease. A complete ophthalmic examination, including uncorrected visual acuity, best spectacle-corrected visual acuity, and contrast sensitivity, was performed 6 months postoperatively. Results were compared with those in 40 eyes with the AcrySof monofocal IOL single-piece IOL. RESULTS In the multifocal group, 90 eyes (90%) had an uncorrected distance visual acuity of 20/25 or better (logMAR<0.10) and an uncorrected near visual acuity at 35 cm of J3 or better (logMAR 0.14). The multifocal group and monofocal group had similar distance uncorrected and best corrected visual acuities; however, the multifocal group had significantly better near uncorrected acuity. The mean contrast sensitivity values were 18.28 dB (static program) and 17.95 dB (dynamic program) in the multifocal group and 19.18 dB (static program) and 21.2 dB (dynamic program) in the monofocal group. CONCLUSIONS The ReSTOR multifocal IOL provided a satisfactory full range of vision; 92% of the patients achieved total spectacle independence. Contrast sensitivity was lower than with the SA60AT monofocal IOL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs.

PURPOSE To compare visual acuity, total and high order wavefront aberrations (coma, spherical aberration, and other terms of high order aberration), and contrast sensitivity in 105 eyes implanted with 4 different types of intraocular lenses (IOLs) (1 multifocal apodized diffractive IOL and 3 monofocal IOLs). METHODS A prospective study comparing four types of IOLs (Alcon ReSTOR [50 eyes], Alc...

متن کامل

Visual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery

The aim of this study was to compare the visual performance of Acrysof ReSTOR and Acrysof Natural intraocular lenses (IOLs) following cataract surgery. A randomized prospective study was performed in which 64 eyes (51 patients) were divided randomly into two groups. Monofocal IOLs (Acrysof Natural) were implanted into 34 eyes (27 patients) and multifocal IOLs (Acrysof ReSTOR) were implanted int...

متن کامل

Disk halo size measured in individuals implanted with monofocal versus diffractive multifocal intraocular lenses

METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in 39 eyes that had cataract surgery and the bilateral implant of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were reco...

متن کامل

Does the apodized diffractive intraocular lens Acrysof ReSTOR Natural interfere with FDT Matrix perimetry results?

PURPOSE To compare the effect of an apodized diffractive intraocular lens (IOL) (Acrysof ReSTOR Natural) and its yellow counterpart (Natural IQ) on frequency doubling technology (FDT) perimetry results. METHODS This study included 37 eyes from 22 patients at the 'Centro Oftalmológico Tranjan' who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReS...

متن کامل

Contrast visual acuity after multifocal intraocular lens implantation: aspheric versus spherical design.

AIM To evaluate contrast visual acuity (CVA) after implantation of an aspheric apodized diffractive intraocular lens (IOL) or a spherical apodized diffractive IOL in cataract surgery. METHOD This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes) and a spherical AcrySof...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 33 7  شماره 

صفحات  -

تاریخ انتشار 2007