Quantitative evaluation of ischemic myocardial scar tissue by unenhanced T1 mapping using 3.0 Tesla MR scanner.

نویسندگان

  • Aylin Okur
  • Mecit Kantarcı
  • Yeşim Kızrak
  • Sema Yıldız
  • Berhan Pirimoğlu
  • Leyla Karaca
  • Hayri Oğul
  • Serdar Sevimli
چکیده

PURPOSE We aimed to use a noninvasive method for quantifying T1 values of chronic myocardial infarction scar by cardiac magnetic resonance imaging (MRI), and determine its diagnostic performance. MATERIALS AND METHODS We performed cardiac MRI on 29 consecutive patients with known coronary artery disease (CAD) on 3.0 Tesla MRI scanner. An unenhanced T1 mapping technique was used to calculate T1 relaxation time of myocardial scar tissue, and its diagnostic performance was evaluated. Chronic scar tissue was identified by delayed contrast-enhancement (DE) MRI and T2-weighted images. Sensitivity, specificity, and accuracy values were calculated for T1 mapping using DE images as the gold standard. RESULTS Four hundred and forty-two segments were analyzed in 26 patients. While myocardial chronic scar was demonstrated in 45 segments on DE images, T1 mapping MRI showed a chronic scar area in 54 segments. T1 relaxation time was higher in chronic scar tissue, compared with remote areas (1314±98 ms vs. 1099±90 ms, P < 0.001). Therefore, increased T1 values were shown in areas of myocardium colocalized with areas of DE and normal signal on T2-weighted images. There was a significant correlation between T1 mapping and DE images in evaluation of myocardial wall injury extent (P < 0.05). We calculated sensitivity, specificity, and accuracy as 95.5%, 97%, and 96%, respectively. CONCLUSION The results of the present study reveal that T1 mapping MRI combined with T2-weighted images might be a feasible imaging modality for detecting chronic myocardial infarction scar tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of small animal cine and scar cardiac magnetic resonance imaging using a clinical 3.0 tesla system

BACKGROUND To evaluate the inter-study, inter-reader and intra-reader reproducibility of cardiac cine and scar imaging in rats using a clinical 3.0 Tesla magnetic resonance (MR) system. METHODS Thirty-three adult rats (Sprague-Dawley) were imaged 24 hours after surgical occlusion of the left anterior descending coronary artery using a 3.0 Tesla clinical MR scanner (Philips Healthcare, Best, T...

متن کامل

MYOCARDIAL INFARCTION AND SCAR T1 Mapping in Patients with Acute Myocardial Infarction

Pixel-by-pixel calculation of T1 values (T1 mapping) has been used in different tissues to focus on T1 changes in a quantitative fashion. The aim of this study was to establish T1 mapping of human myocardium on a 1.5 Tesla system and to examine its diagnostic potential in patients with acute myocardial infarction (AMI). 8 patients with reperfused AMI (day 3 ^ 1) underwent multi-breath-hold MRI ...

متن کامل

Assessment of acute myocardial ischemia with unenhanced T1 mapping MR imaging

Methods 8 rats had an inflatable balloon coronary occluder surgically inserted via thoracotomy. They were allowed to recover for 10-14 days. MRI was performed to obtain baseline measurement of ventricular function. T1 mapping was performed using the Small-Animal LookLocker Inversion Recovery (SALLI) technique. Without removing the animals from the scanner, the left coronary artery was occluded ...

متن کامل

In-Vitro Evaluation of Pre- and Post-Compression States of Human Articular Cartilage Using MRI at 3 Tesla

The purpose of this study was to evaluate changes of several MR parameters (T1, T2 and ADC) before and after compression in human cartilage samples using unique microimaging compression system. Cartilage samples were prepared from joints of 10 patients, who underwent a total knee joint replacement. Study was performed on a Bruker 3T Medspec whole-body scanner (Bruker, Ettlingen, Germany) using ...

متن کامل

Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice

OBJECT To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T1 mapping in mice using a 3T MRI scanner. MATERIALS AND METHODS To allow high-resolution T1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2014