Identification of the lumbar interspinous spaces by palpation and verified by X-rays.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Palpation has been shown to be rather inaccurate at identifying lumbar interspinous spaces in neuraxial anesthesia. The aim of this study is to assess the accuracy of the determination of the lumbar interspinous spaces by anesthesiologist's palpation using postoperative X-rays in obstetric patients. METHODS We reviewed the anesthetic record and the post-operative abdominal X-rays of the cesarean sections. We indwelled the epidural catheter for post-operative one-shot analgesia. We included combined spinal and epidural anesthesia cases and compared the interspinous level which the anesthesiologist recorded and the epidural catheter insertion level confirmed by abdominal X-ray for each case. We also evaluated the factors (age, body weight, height, Body Mass Index, gestational age, and the type of surgery [planned / emergency]) leading to misidentification of interspinous level. RESULTS Nine hundred and sixty seven cesarean sections were performed and a total of 835 cases were evaluated. The levels of the puncture documented by the anesthesiologists were in agreement with the actual catheter insertion levels in 563 (67%) cases. When the anesthesiologists aimed at L2-3 level, we found the catheter insertion at L1-2 in 5 cases (4.9%), none of which had any post-operative neurological deficits. No variables evaluated were significantly associated with misidentification of interspinous level by the anesthesiologists. CONCLUSIONS There was a discrepancy between the anesthesiologists' estimation by palpation and the actual catheter insertion level shown in X-rays. It seems to be safer to choose the interspinous level L3-4 or lower in spinal anesthesia.
منابع مشابه
Identification of the lumbar interspinous spaces: palpation versus ultrasound.
BACKGROUND Palpation has been shown to be inaccurate at identifying lumbar interspinous spaces. Our goal in this study was to compare ultrasound imaging of the region to palpation. METHODS Using ultrasound in the postpartum period, we estimated the interspinous level used for obstetric neuraxial anesthesia in 121 women and compared this estimation with the level estimated by palpation and doc...
متن کاملAnatomy of Lumbar Interspinous Ligaments: Attachment, Thickness, Fibre Orientation and Biomechanical Importance
Literature related to the study of interspinous ligament in the lumbar region is sparse. Very few studies have elucidated the fibre orientation of this ligament at different lumbar levels. Male (19) and female (6) cadavers were dissected to expose the interspinous ligaments beneath all the lumbar vertebrae. Fibre attachments and directions were observed at all lumbar interspinous spaces. Thickn...
متن کاملThe cost effectiveness of dynamic and static interspinous spacer for lumbar spinal stenosis compared with laminectomy
Background: The present study aims to evaluate the cost-effectiveness of Dynamic Interspinous Spacer (Coflex®) and Static Spacer (X-STOP ®) compared to Laminectomy (LAMI) in patients with lumbar spinal stenosis. Methods: A decision-analysis model was developed to estimate the cost-effectiveness. The effectiveness parameters were obtained from a systematic literature review in ...
متن کاملCorrelating Motion Palpation with Functional X-ray Findings in Patients with Low Back Pain
Objectives: To determine whether a correlation between motion palpation findings and abnormal coupling patterns, as viewed in lumbar functional X-rays, can be demonstrated in low back pain (LBP) patients.Design: A prospective observational study of patients who present to a chiropractic clinic for assessment of low back pain.Subjects: The sample population consisted of 27 consecutive patients p...
متن کاملInvestigating the effect of voltage fluctuations on the beam quality of X-rays in the range energy of diagnostic radiology
The purpose of this study was to investigate the effect of voltage ripple produced by X-ray machines on the quality of X-ray rays. For this purpose, the energy spectrum from the X-ray tube manufacturer should be simulated in the range of diagnostic radiography and verified by experimental results. The statistical analysis of the results showed that there is no significant difference between sim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of anesthesiology
دوره 63 3 شماره
صفحات -
تاریخ انتشار 2013