Feasibility of Decentralised Deployment of Xpert MTB/RIF Test at Lower Level of Health System in India

نویسندگان

  • Neeraj Raizada
  • K. S. Sachdeva
  • Achuthan Sreenivas
  • Bhavin Vadera
  • R. S. Gupta
  • Malik Parmar
  • Shubhangi Kulsange
  • Ameet Babre
  • Rahul Thakur
  • Christen Gray
  • Ranjani Ramachandran
  • Umesh Alavadi
  • Mayank Ghedia
  • Balasangameshwara Vollepore
  • Puneet Dewan
  • Catharina Boehme
  • C. N. Paramsivan
چکیده

BACKGROUND Xpert MTB/RIF is an automated cartridge-based nucleic acid amplification test that has demonstrated its potential to detect tuberculosis and rifampicin resistance with high accuracy. To assist scale-up decisions in India, a feasibility assessment of Xpert MTB/RIF implementation was conducted within microscopy centres of 18 RNTCP TB units. METHODS As part of programme-based demonstration of Xpert MTB/RIF implementation, we recorded and analysed association between key implementation factors and the ability of test to produce valid results. Factors contributing to test failures were analysed from GeneXpert software data which provides 'failure codes' and causes for test failures. RESULTS From March'12 to January'13, total 40,035 suspects were tested by Xpert MTB/RIF, and 39,680 (99.1%) received valid results (Cumulative: 37157 (92.8%) on first attempt, 39410 (98.4%) on second attempt, 39637 (99.0%) on third attempt and 39680 (99.1%) on more attempts). Overall initial test failure was 2,878 (7.2% (4%-17%)); of these, 2,594 (90.1%) were re-tested and produced valid results. Most frequent reason of test failure was inadequate sample processing or equipment malfunction (3.9%). Other reasons included power failure (1.1%), cartridge integrity/component failure (0.8%), device-computer communication error (0.5%), and temperature-related errors (0.08%). Significant variation was observed in failure rates both across instruments and over time; furthermore, substantial variation was observed in failure rate in two cartridges lots. CONCLUSION Installation required minimal infrastructure modifications and concerns about adequacy of human resources under public sector facilities and temperature extremes proved unfounded. Under routine conditions, Xpert MTB/RIF provided 99.1% valid results in TB suspects with low overall failure rates (7.2% initial failure, 0.9% final failure); devices provided valuable real-time feedback on reasons for test failure, which were used for rapid corrective action. High modular replacement (32%) and inter-lot cartridge performance variation remain sources of concern, and warrant close monitoring of failure rates as a key quality indicator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catching the Missing Million: Experiences in Enhancing TB & DR-TB Detection by Providing Upfront Xpert MTB/RIF Testing for People Living with HIV in India

BACKGROUND A critical challenge in providing TB care to People Living with HIV (PLHIV) is establishing an accurate bacteriological diagnosis. Xpert MTB/RIF, a highly sensitive and specific rapid tool, offers a promising solution in addressing these challenges. This study presents results from PLHIV taking part in a large demonstration study across India wherein upfront Xpert MTB/RIF testing was...

متن کامل

Use of Xpert MTB/RIF in Decentralized Public Health Settings and Its Effect on Pulmonary TB and DR-TB Case Finding in India

BACKGROUND Xpert MTB/RIF, the first automated molecular test for tuberculosis, is transforming the diagnostic landscape in high-burden settings. This study assessed the impact of up-front Xpert MTB/RIF testing on detection of pulmonary tuberculosis (PTB) and rifampicin-resistant PTB (DR-TB) cases in India. METHODS This demonstration study was implemented in 18 sub-district level TB programme ...

متن کامل

Enhancing TB Case Detection: Experience in Offering Upfront Xpert MTB/RIF Testing to Pediatric Presumptive TB and DR TB Cases for Early Rapid Diagnosis of Drug Sensitive and Drug Resistant TB

BACKGROUND Diagnosis of pulmonary tuberculosis (PTB) in children is challenging due to difficulties in obtaining good quality sputum specimens as well as the paucibacillary nature of disease. Globally a large proportion of pediatric tuberculosis (TB) cases are diagnosed based only on clinical findings. Xpert MTB/RIF, a highly sensitive and specific rapid tool, offers a promising solution in add...

متن کامل

Feasibility, diagnostic accuracy, and effectiveness of decentralised use of the Xpert MTB/RIF test for diagnosis of tuberculosis and multidrug resistance: a multicentre implementation study

BACKGROUND The Xpert MTB/RIF test (Cepheid, Sunnyvale, CA, USA) can detect tuberculosis and its multidrug-resistant form with very high sensitivity and specificity in controlled studies, but no performance data exist from district and subdistrict health facilities in tuberculosis-endemic countries. We aimed to assess operational feasibility, accuracy, and effectiveness of implementation in such...

متن کامل

A Comparison of Multidrug-Resistant Tuberculosis Treatment Commencement Times in MDRTBPlus Line Probe Assay and Xpert® MTB/RIF-Based Algorithms in a Routine Operational Setting in Cape Town

BACKGROUND Xpert MTB/RIF was introduced as a screening test for all presumptive tuberculosis cases in primary health services in Cape Town, South Africa. STUDY AIM To compare multidrug-resistant tuberculosis (MDR-TB) treatment commencement times in MDRTBPlus Line Probe Assay and Xpert MTB/RIF-based algorithms in a routine operational setting. METHODS The study was undertaken in 10 of 29 hig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014