Restenosis of endovascular stents from stent compression.

نویسندگان

  • K Rosenfield
  • R Schainfeld
  • A Pieczek
  • L Haley
  • J M Isner
چکیده

OBJECTIVES We sought to determine the basis for restenosis within superficial femoral arteries (SFAs) and hemodialysis conduits treated with balloon-expandable stents. BACKGROUND Use of stents within coronary and peripheral vessels continues to increase exponentially. The mechanism of restenosis within stents placed at various vascular sites is not well understood. In particular, the implications of deploying a balloon-expandable stent in a compressible site are not well understood. METHODS After the serendipitous detection of stent deformation during intravascular ultrasound (IVUS) examination of a restenosed dialysis fistula, we evaluated a consecutive series of patients with stents placed in compressible vascular sites, including the SFA (six patients) and hemodialysis fistulae (five patients). Clinical, angiographic and IVUS examinations were performed to evaluate mechanisms of restenosis. RESULTS Stent compression was identified as the principal cause of restenosis in all dialysis conduits and SFAs. Stent deformity was not reliably identified by angiography; however, IVUS identified compression of two forms: eccentric deformation, implicating two-point compressive force, and complete circumferential encroachment of stent struts around the catheter, suggesting multidirectional compressive force. Despite redilation, secondary restenosis resulting from recurrent compression recurred in most sites. CONCLUSIONS Restenosis within balloon-expandable endovascular stents may occur as a result of stent compression, a phenomenon readily detected by IVUS, but often not by angiography. These findings have significant implications for the use of balloon-expandable stents within vascular sites subject to extrinsic compression, such as hemodialysis conduits, the adductor canal segment of the SFA and carotid arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents.

PURPOSE To investigate the incidence, anatomical location, and clinical impact of fractures and/or compression of infrapopliteal balloon-expandable metal stents implanted for critical limb ischemia (CLI) treatment. METHODS This prospective study included 63 CLI patients (45 men; mean age 71.3+/-9.5 years) who had been treated with infrapopliteal angioplasty and stent placement for 191 lesions...

متن کامل

In-Stent Restenosis After Femoropopliteal Interventions With Drug-Eluting Stents: Same But Different?

SEE PAGE 828 T he superficial femoral artery (SFA), the longest artery in the human body, is subjected to nearly constant torsion, bending, and compression. It is perhaps natural to expect it to be the Achilles heel of endovascular interventions, plagued by higher rates of in-stent restenosis (ISR) compared to other arterial beds. Indeed, the 12-month rates of ISR after implantation of modern b...

متن کامل

Redilation of endovascular stents in congenital heart disease: factors implicated in the development of restenosis and neointimal proliferation.

OBJECTIVES We sought to determine the incidence of and risk factors for the development of restenosis and neointimal proliferation after endovascular stent implantation for congenital heart disease (CHD). BACKGROUND Risk factors for the development of restenosis and neointimal proliferation are poorly understood. METHODS This was a retrospective review of patients who underwent endovascular...

متن کامل

Comparison of second-generation stents for application in the superficial femoral artery: an in vitro evaluation focusing on stent design.

PURPOSE To examine and compare in an ex vivo study different nitinol stent designs intended for the superficial femoral artery (SFA) with regard to the appearance of fracture. METHODS Seven different 8-×40-mm nitinol stents were evaluated (Misago, Absolute, Smart, Luminexx, Sentinol, Lifestent NT, and Sinus-Superflex). Finite element analysis (FEA) was used for digitalized stent design compar...

متن کامل

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 1997