Piet Mondrian’s Broadway Boogie Woogie: non invasive analysis using macro X-ray fluorescence mapping (MA-XRF) and multivariate curve resolution-alternating least square (MCR-ALS)

نویسندگان

  • Ana Martins
  • Cynthia Albertson
  • Chris McGlinchey
  • Joris Dik
چکیده

Piet Mondrian’s Broadway Boogie Woogie (1942–1943) was examined using Macro X-Ray Fluorescence mapping (MA-XRF) to help characterize the artist’s materials and understand his creative process as well as the current condition issues of the painting. The presence and distribution of key chemical elements was used to identify the main pigments in the different paint layers and under-layers, namely titanium white/barium sulfate, zinc white, bone black, cadmium yellow and/or cadmium-zinc yellow, cadmium red and/or cadmium-barium red and ultramarine. The XRF data was also examined using a multivariate curve resolution-alternating least square (MCR-ALS) approach to virtually separate and help characterize the different paint layers. Results suggest that Broadway Boogie Woogie was originally conceived as an asymmetrical grid of interlacing red and yellow bars. Mondrian then reworked the composition extensively breaking the bars by painting small squares in red, blue and gray and repainting them over and over again changing their size, color or tonality, and by adding and reworking large colored shapes in the background. Mondrian scraped off the paint in some areas before making adjustments to the composition but did not do it consistently throughout the painting. The yellow paint on the surface is severely cracked. Wherever red paint has been covered with yellow paint, it has oozed through the cracks in the top layer. The results illustrate how the MA-XRF / MCR-ALS approach can complement the examination of a painting and contribute to the understanding of the artist’s process and choice of materials in a non-invasive way.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples

Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...

متن کامل

MCR of the quenching of the EEM of fluorescence of Aflatoxins (B1, G1) by Gold nanoparticles

In This research, gold nanoparticles were synthesized and functionalized by the antibody of aflatoxins. The quenching of the fluorescence of excitation emission matrices (EEM) of two type of aflatoxins (B1, G1), provoked by the gold nanoparticles, was studied by principal component analysis (PCA) and multivariate curve resolution with alternating least squares (MCR-ALS). These aflatoxins show q...

متن کامل

MCR of the quenching of the EEM of fluorescence of Aflatoxins (B1, G1) by Gold nanoparticles

In This research, gold nanoparticles were synthesized and functionalized by the antibody of aflatoxins. The quenching of the fluorescence of excitation emission matrices (EEM) of two type of aflatoxins (B1, G1), provoked by the gold nanoparticles, was studied by principal component analysis (PCA) and multivariate curve resolution with alternating least squares (MCR-ALS). These aflatoxins show q...

متن کامل

Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...

متن کامل

Application of multivariate curve resolution alternating least squares (MCR-ALS) to the quantitative analysis of pharmaceutical and agricultural samples.

Application of multivariate curve resolution alternating least squares (MCR-ALS), for the resolution and quantification of different analytes in different type of pharmaceutical and agricultural samples is shown. In particular, MCR-ALS is applied first to the UV spectrophotometric quantitative analysis of mixtures of commercial steroid drugs, and second to the near-infrared (NIR) spectrophotome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017