Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
نویسندگان
چکیده
The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta diameter index in a sonographic hydration assessment. The study enrolled 50 young students at the age of 19-26 (the median age was 22.95) including 27 women and 23 men. The volunteers were examined in the supine position with GE Logiq 7 system and a convex transducer with the frequency of 2-5 MHz. The measurements were performed in the longitudinal and transverse planes by two inexperienced examiners - the authors of this paper, following a four-hour training conducted by an experienced sonographer. The longitudinal values of the inferior vena cava/aorta diameter index obtained in this study were similar to those found in the literature. The reference value for the inferior vena cava/aorta index determined by Kosiak et al., which constituted 1.2 ± 2 SD, for SD = 0.17, was similar to the values obtained by the authors of this paper which equaled 1.2286 ± 2 SD, for SD = 0.2. The article presented below proves that measuring the inferior vena cava/aorta diameter index is not a complex examination and it may be performed by physicians with no sonographic experience. Furthermore, the paper demonstrates that the inferior vena cava/aorta diameter index measured in the transverse plane is similar to the inferior vena cava/aorta diameter index determined in the longitudinal plane. Thus, both measurements may be used interchangeably to assess the hydration status of patients.
منابع مشابه
Sonographic assessment of the inferior vena cava/aorta index measured with the transducer placed in the anterior median line and right anterior axillary line – a comparison
UNLABELLED The aim of the study was to compare the values of the sonographic inferior vena cava/ aorta index obtained with the transducer placed in the median line and right anterior axillary line. MATERIAL AND METHODS The study enrolled 45 volunteers, including 33 women, aged 22.5 ± 1.26 with a negative history of circulatory and renal diseases. The study consisted in a sonographic assessmen...
متن کاملA comparison of the ultrasound measurement of the inferior vena cava obtained with cardiac and convex transducers
Background Ultrasound measurement of the inferior vena cava diameter and its respiratory variability are amongst the predictors of fluid volume status. The primary purpose of the present study was to compare the consistency of inferior vena cava diameter measurements and the collapsibility index, obtained with convex and cardiac transducers. A secondary aim was to assess the agreement of the pa...
متن کاملThe efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation
Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...
متن کاملUltrasonographic Assessment of Caudal Vena Cava to Aorta Ratio as a Novel Endpoint in Hemorrhagic Shock Resuscitation in Dogs
Objective- The aim of this study was to assess ultrasonography-derived caudal vena cava to aorta ratio (CVC/Ao) as a novel endpoint in the resuscitation of experimental hemorrhagic shock in dogs. Design- Experimental study. Animals- Ten adult mongrel healthy dogs. Procedures- After induction of anesthesia (con...
متن کاملUsefulness of ultrasound examination in the evaluation of a neonate's body fluid status
UNLABELLED Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. MATERIAL AND METHODS Th...
متن کامل