چکیده

A dynamic hip screw (DHS) remains the implant of choice for stabilization of trochanteric fractures because of its favourable results and low rate of non-union or hardware failure, but complication rates of the DHS are higher in unstable and osteoporotic trochanteric fractures. The proponents of the dynamic helical hip system (DHHS) report that it has the potential to decrease the cut-out rates in such fractures as helical blade allows compaction in osteoporotic femoral head which in itself improves anchorage. The purpose of the present study was to evaluate the radiological and functional outcome of DHHS in unstable and osteoporotic trochanteric fractures. This was a prospective observational study. The mean age of the 51 patients (24 men and 27 women) was 72.8 years. Fractures were type AO31A2.2 in 28 patients and AO31A2.3 in 23 patients. According to DEXA scans, 41 patients had osteoporosis and 10 patients had osteopenia. Osteoporosis was grade 3 in 36 patients and grade 2 in 15 patients according to Singh's index. The mean follow-up was 1.84 years. The average sliding of the lag screw was 3.6 mm (range 2-10 mm). The mean operative time was 54.74 (range 48-65) min. The average tip-apex distance was 20.24 mm (range 12-28 mm). All but one fractures united. The average time to union was 13.14 (range 11-24) weeks. There were four mechanical complications namely late helical blade migration (n = 1), late medialization of shaft (n = 2) and varus collapse with cut through (n = 1). No patient was noted to have a plate pull-out. The average Harris hip score was 92.87 (range 76-97). The use of a DHHS for stabilization of unstable(AO31A2), osteoporotic trochanteric fractures in the elderly patients was associated with reliable rates of union and functional outcome and a decreased incidence of screw cut-out and side plate pull-out.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Early experience of dynamic hip screw with spiral blade and locking side plate for the stabilization of trochanteric fractures.

OBJECTIVE To evaluate early experience with helical hip system in osteoporotic elderly patients with per-trochanteric fractures. METHODS The retrospective study was conducted at Aga Khan University Hospital, Karachi, and comprised records of patients having low-velocity pertrochanteric fractures who were fixed with spiral blade Dynamic Helical Hip Systemfrom July to December 2014 and were fol...

متن کامل

How to Treat the Complex Unstable Intertrochanteric Fractures in Elderly Patients? DHS or Arthroplasty

Background:  Due to difficulty in obtaining anatomical reduction, management of the unstable intertrochanteric fractures in elderly osteoporotic patients is challenging. The purpose of this study is to compare the results of hip arthroplasty (total, hemi, or bipolar) with DHS in the elderly patients with unstable intertrochanteric fractures.   Methods:  We prospectively studied and followed-up ...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Resorbable cement for the augmentation of internally-fixed unstable trochanteric fractures. A prospective, randomised multicentre study.

We undertook a multicentre, prospective study of a series of 112 unstable trochanteric fractures in order to evaluate if internal fixation with a sliding screw device combined with augmentation using a calcium phosphate degradable cement (Norian SRS) could improve the clinical, functional and radiological outcome when compared with fractures treated with a sliding screw device alone. Pain, acti...