Power-Assisted Liposuction (P.A.L.) Fat Harvesting for Lipofilling: The Trap Device
نویسندگان
چکیده
DEAR EDITOR Coleman classically described four phases in fat grafting including harvesting, refinement, transfer and placement. The harvesting phase can be simplified by using the “trap device” instead of the conventional 10-cc Luer-Lock syringes. The “trap device” for harvesting fat by Power Assisted Liposuction and Medinorm tank is a convenient, wholly sterile, time saving method to provide fat for lipostructure in various part of the body.1 The harvesting phase can be simplified by using Power-Assisted Liposuction (P.A.L.) instead of the conventional 10-cc Luer-Lock syringes.2 This study evaluated the trap device of P.A.L. in fat harvesting for lipofilling. MicroAire P.A.L.TM (MicroAire Surgical Instruments LLC, 1641 Edlich Drive Charlottesville, VA 22911) is an electric device for liposuction, composed of a motorized handle (mod. 600-E) connected to an aspiration cannula of varying size and types, a standard plastic tubing for fat aspiration, and an electric control console (mod. 1020). The P.A.L. produces oscillating reciprocal “to-and-fro” movements of the cannula tip2 with a 2,4 millimetres stroke and a 0 to 4500/min vibration range. We thought the same system would find ready application to fat harvesting if an efficient sterile fat trap could be fashioned. Thus, instead of directly connecting the plastic suction tube to a common aspirator, we deviced a trap composed of the reservoir of an “High Vacuum Wound Drainage System” of 600 cc (Medinorm Medizintechnik GmbH, Gewerbepark 7–9, D-66583 Spiesen-Elversberg, Germany) deprived of its two rubber caps. The P.A.L. tube was connected to the longest of the two beaks of the 600 cc reservoir by using the forefinger of a surgical glove as a gasket (both tube and beak were stiff and they otherwise would not fit one another); the other beak was directly connected with the tube of the customary aspirator. To avoid leaks and loss of suction, two small Opsites TM (Smith and Nephew, Inc 1450 E Brooks Rd Memphis, TN 38116) were used as an “insulating tape” around the two connections. The P.A.L. harvesting cannulas that we employed were a single-hole MicroAire of 3 mm in diameter (PAL-R300LS single-port) and a triple-hole MicroAire of 4 mm (PAL-R402LS Triport II) (Figure 1). In a 38 years old patient (1.75 cm tall, weighing 57 kg, with a body mass index of 18.6) undergoing lipostructure for a severe pectus excavatum, we easily harvested high quality fat from both medial knees and the abdomen, after infiltration with 500 ml of a modified Klein formula (a dilution solution of 1% lidocaine, 50 ml), Letter to Editor
منابع مشابه
Fat Harvest Using a Closed-Suction Drain
We propose a safe, simple, and novel method to harvest fat using a standard liposuction cannula and a Redivac or alternative closed-suction drain. The authors have used this technique for both 'dry' and 'wet' liposuction. This technique is both easy to perform and cost-effective whilst providing both a silent and relatively atraumatic fat harvest. The lower negative pressure compared with tradi...
متن کاملOne stage rescue procedure after capsular contracture of breast implants with autologous fat grafts collected by water assisted liposuction (“BEAULI Method”)
With increasing number of patients with silicone implants for breast augmentation or reconstruction we are confronted with more and more cases of capsular contracture. Not every case is resolved by resection of the capsule and exchange of implants. Many patients rather bear the consequences of severe fibrosis than to have their implants removed. The one stage procedure of implant removal and li...
متن کاملDoes Water - Jet Force Make a Difference in Fat Grafting ? In Vitro and In Vivo Evidence of Improved Lipoaspirate Viability and Fat Graft Survival EXPERIMENTAL
127 Autologous fat grafts have been used to treat tissue deficiencies for over 100 years.1 They have been considered the ideal softtissue filler by most investigators, because they are inexpensive, abundant, and easy to obtain.2 However, the potential high absorption rate (25 to 90 percent) of grafted fat, which may be attributable to damage to the grafts caused by tissue harvesting and graftin...
متن کاملProcedure, applications, and outcomes of autologous fat grafting
OBJECTIVE To systematically review the procedure, applications, and outcomes of autologous fat grafting, a promising technique with various clinical applications. PATIENTS AND METHODS Literature review of publications concerning autologous fat grafting. RESULTS Since its introduction, lipofilling has become increasingly popular; however, its results are variable and unpredictable. Several m...
متن کامل