Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.

نویسندگان

  • C J Harvey
  • M J O'Doherty
  • C J Page
  • S H Thomas
  • T O Nunan
  • D F Treacher
چکیده

Increased delivery of aerosol to a model lung (attached to a mechanical ventilator) has been demonstrated with an ultrasonic nebulizer as compared to a jet nebulizer. This study examined whether the increased aerosol deposition with an ultrasonic nebulizer could also be demonstrated in vivo. Seven patients (6 male and 1 female) were studied during mechanical ventilalion (Siemens Servo 900C, Middlesex, UK) after open heart surgery. Two studies were performed in each patient. In the first study, aerosol was delivered via a Siemens Servo 945 nebulizer system (high setting) driving a System 22 Acorn jet nebulizer (Medic-Aid, Sussex, UK) containing 3 mL (99m)technetium-labelled human serum albumin (99mTc-HSA) (50 microg; activity 74 MBq). In the second study, a DP100 ultrasonic nebulizer (DP Medical, Meylan, France) containing 12 mL 99mTc-HSA (50 microg; activity 185 MBq) was used. Pulmonary deposition was quantified using a gamma camera. The humidification of the circuit and the ventilator settings were kept constant according to the patient's clinical requirements. The total lung aerosol deposition (mean+/-SD), as a percentage of initial nebulizer activity, was greater using the ultrasonic nebulizer than using the jet nebulizer (53+/-1.4 vs 2.3+/-0.9%; p<0.002). The ultrasonic nebulizer was also associated with a reduction in the time required to complete nebulization (9 vs 21 min, respectively) (p<0.0001). Use of the DP100 ultrasonic nebulizer more than doubled lung deposition compared with the System 22 jet nebulizers in mechanically-ventilated patients. Their efficiency, speed of drug delivery, and compatibility with mechanical ventilator circuits make ultrasonic nebulizers potentially attractive for use during mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.

BACKGROUND The type of aerosol generator and the position in the ventilator circuit are crucial to determine aerosol delivery during mechanical ventilation. We compared lung deposition of albuterol aerosols generated by 4 different nebulizers placed in-line in 4 different positions in a pediatric ventilator model. METHODS Two brands of continuously operated jet nebulizer (6 L/ min, oxygen), a...

متن کامل

High impact aerosol technology offers higher efficiency, but is not ready for prime time.

The therapeutic administration of medical aerosols has been a standard adjunct to treatment of critically ill patients since positive-pressure mechanical ventilators were introduced over 60 years ago, and most ventilators can operate a jet nebulizer in synchrony with mechanically delivered breaths. However, for the first 40 years, little was known about the efficiency of aerosol delivery during...

متن کامل

Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation.

BACKGROUND The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. METHODS Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model o...

متن کامل

Radioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects.

BACKGROUND In vivo deposition studies of aerosol administration during noninvasive ventilation (NIV) are scarce in the literature. The aim of this study was to compare radioaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radio-tagged aerosol administered using vibrating mesh nebulizers and conventional jet nebulizers during N...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 1997