Study of forensic and clinical source hemoglobin interference with the duPont aca ethanol method.

نویسنده

  • R H Gadsden
چکیده

The enzymatic alcohol (ethanol, ALC) analytical pack for the duPont aca is intended primarily for the analysis of serum or plasma samples containing no visibly detectable free hemoglobin (non-hemolyzed samples). It has become apparent, through clinical and medicolegal consultation, that this methodology has been applied for assay of ethanol content in hemolyzed samples (sample sources: clinical and forensic cases). The influence of sample free hemoglobin on the ace ethanol method was investigated. With 'hemolyzed' clinical samples (containing primarily oxyhemoglobin) a significant decrease was found in known ethanol concentration at 0.5 g per dl and greater of hemoglobin with the influence being greatest at lower ethanol concentration. With forensic samples (containing varying amounts of oxy-, reduced, and methemoglobins), the same observation was made with measured decrease in ethanol concentration beginning at 0.1 g per dL hemoglobin and greater. In essence, the higher the sample hemoglobin concentration the greater would be the effect in decreasing the apparent ethanol concentration. Preparation of protein-free trichloroacetic acid supernatants and their assay on the aca and by head-space gas chromatography resulted in excellent recovery of the sample ethanol. It is concluded that the effect of sample free hemoglobin is spectral in nature, and its presence results in potential and real overblanking for the aca ethanol enzymatic reaction sequence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of the DuPont aca as exemplified by a new procedure for neonatal total bilirubin.

Hemoglobin interferes with determination of total bilirubin by the diazo procedure with the DuPont aca. We compared results by that procedure with those by a manual direct spectrophotometric two-wavelength method. Because the manual method was not inhibited by hemolysis as was the DuPont aca diazo procedure, we reprogrammed our DuPont aca to measure the absorbance of diluted serum samples at 45...

متن کامل

Evaluation of the DuPont aca amylase method.

The dilution/activity curve for the DuPont aca kinetic amylase (EC 3.2.1.1) method is linear to approximately six times the upper limit of the expected range. Total reaction time on the aca is 4.3 min; however, there is a nonlinear rate of change in absorbance for at least the first 8 min, which is consistent with a lag phase. The within-run and day-to-day coefficients of variation were 2.4% at...

متن کامل

Biochemical Markers of Acute and Chronic Ethanol Use: Forensic and Clinical Applications

Background: The analysis of ethanol in bio-samples is an important method for determination of acute alcohol use/abuse both in clinical and forensic toxicology. In forensic cases, it is known that micro-organisms involved in the postmortem putrefaction process can produce alcohol and when the body has been traumatized. In clinical setting, post-ingestion time has a critical role for determinati...

متن کامل

Changes in Some Hematology Parameters in poisoning with Rice Tablet (Aluminum Phosphide)

Abstract      Background and Objective: Aluminum Phosphide (ALP) is a solid non-organic phosphide with dark gray or dark yellow crystals. It reacts with stomach acid after ingestion and causes phosphine gas to be released. It is thought that phosphine causes toxicity from enzymatic interference and may even lead to cell death. This study aimed to investigate the eff...

متن کامل

Abbott radiative energy attenuation method for quantifying ethanol evaluated and compared with gas-liquid chromatography and the Du Pont aca.

Quantification of ethanol by a radiative energy attenuation (REA) technique was evaluated and compared with results by gas-liquid chromatography (GLC) and by the Du Pont aca. Within-assay CVs were less than 5.5%. Between-assay CVs ranged from 1.9% to 6.0% for serum and blood controls at concentrations of 0.5, 1.0, and 2.5 g/L. We observed no cross reactivity with methanol, isopropanol, or aceto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 1986