False aneurysm of the superficial femoral artery following minimally invasive plate osteosynthesis of a femoral shaft fracture.
نویسندگان
چکیده
We present the case of a 50-year-old man who developed a delayed progressive swelling over the medial aspect of his right thigh, six weeks following minimally invasive plate osteosynthesis (MIPO) of a supracondylar femur fracture. Angiography showed a false aneurysm of the superficial femoral artery, caused by progressive displacement of a butterfly fragment. Open vascular repair was performed and the sharp edge of the butterfly fragment was removed.
منابع مشابه
Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...
متن کاملMinimally Invasive Plate Osteosynthesis for Periprosthetic Distal Femoral Fractures after Total Knee Arthroplasty
PURPOSE To evaluate the outcomes of the treatment of distal femoral fractures using minimally invasive plate osteosynthesis following total knee arthroplasty (TKA). MATERIALS AND METHODS From July 2008 to October 2011, 14 patients were treated with minimally invasive plate osteosynthesis for periprosthetic fractures following TKA. The mean duration of follow-up was 19.2 months and the mean ag...
متن کاملA Case Report of Ruptured Superficial Femoral Artery Aneurysm
Single superficial femoral artery (SFA) aneurysm is rare and occurs in approximately 5 per 100,000 patients. Rupture is a rare complication in this aneurysm. In this case report, we present the diagnostic and therapeutic work up of a ruptured SFA aneurysm of the right lower limb in a 75-year-old diabetic man with ischemic heart disease. Pre-surgical diagnosis was through physical examination fi...
متن کاملFalse Aneurysm of the Common Femoral Artery in an Infant after a Phlebotomy
False Aneurysms are uncommon in the pediatric population. We report a case of false aneurysm of the common femoral artery (CFA) after accidental arterial puncture, during a phlebotomy for blood sample. The lesion was surgically resected and arterial continuity restored by end to end anastomosis. The postoperative course was uneventful.
متن کاملTreatment of distal femoral fractures in elderly diabetic patients using minimally invasive percutaneous plating osteosynthesis (MIPPO).
The aim of this study was to evaluate the results of minimally invasive percutaneous plate osteosynthesis (MIPPO) of distal femoral fractures in elderly diabetic patients with osteoporotic bone. Thirteen supracondylar or intercondylar femoral fractures were treated by MIPPO with a locked plate without bone grafting. All fractures healed, with only one delayed union in a patient who had deep inf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 74 5 شماره
صفحات -
تاریخ انتشار 2008