Novel use of an exchange catheter to facilitate intubation with an Aintree catheter in a tall patient with a predicted difficult airway: a case report
نویسندگان
چکیده
INTRODUCTION The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has been shown to successfully facilitate difficult intubations when other methods have failed. The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has a fixed length of 56 cm, and it has been suggested in the literature that it may be too short for safe use in patients who are tall. CASE PRESENTATION We present the case of a 32-year-old, 180 cm tall Caucasian woman with a predicted difficult airway who presented to our facility for an emergency cesarean section. After several failed intubation attempts via direct laryngoscopy, an airway was established with a laryngeal mask airway. After delivery of a healthy baby, our patient's condition necessitated tracheal intubation. A fiber-optic bronchoscope loaded with an Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) was passed through the laryngeal mask airway into the trachea until just above the carina, but was too short to safely allow for the passage of an endotracheal tube. CONCLUSIONS We present a novel technique in which the Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) was replaced with a longer (100 cm) exchange catheter, over which an endotracheal tube was passed successfully into the trachea.
منابع مشابه
Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway
Purpose: To present a case where the Aintree intubation catheter was used in conjunction with the Laryngeal Mask Airway (LMA) and a fiberoptic bronchoscope (FOB) in a patient with an unexpected difficult airway. Clinical Features: A 38 year old 90 kg man scheduled for nasal endoscopy with ethmoidectomy under general anesthesia was found to be unexpectedly difficult to intubate using a both a MA...
متن کاملAirway Management in a Patient with Severe Ankylosing Spondylitis Causing Bamboo Spine: Use of Aintree Intubation Catheter.
Management of a case of ankylosing spondylitis can be very challenging as the airway and the central neuraxial blockade are extremely difficult to handle. Fiberoptic intubation may lead to predictable success in the face of difficult airway. We are presenting a new technique of fiberoptic intubation in a young patient, suffering from severe ankylosing spondylitis, came for total hip replacement...
متن کاملCorrection to: Local block and Awake Intubation in a Patient with Laryngeal Mass and Anticipated Difficult Airway: A Case Report
Correction to: Local block and Awake Intubation in a Patient with Laryngeal Mass and Anticipated Difficult Airway: A Case Report Hooshang Akbari1, Ravanbakhsh Esmaeili2 1 Assistant Professor, Department of Anesthesiology, Faculty of Paramedical, Mazandaran University of Medical Sciences, Sari, Iran 2 Assistant Professor, Department of Medical Surgical Nursing...
متن کاملRepositioning a displaced tracheostomy tube with an Aintree intubation catheter mounted on a fibre-optic bronchoscope.
Although tracheostomy tube displacement is uncommon, the management is often difficult and the associated mortality is high. It is important to ensure that the airway is secure and then either replace or reposition the tracheostomy tube. This case report describes the use of an Aintree intubation catheter (C-CAE-19.0-56-AIC, William Cook Europe, Denmark) mounted on an intubating fibre-optic bro...
متن کاملPlacement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
During insertion of the double lumen tube in patients with cervical vertebral fixation, the cervical neutral position should be maintained. Although flexible fiberoptic bronchoscopic intubation is the gold standard, novel techniques are needed to facilitate intubation of patients with cervical vertebral fixation in neutral position according to institutional capabilities. In this case report, i...
متن کامل