Porosity of Bleb Capsule declines rapidly with Fluid Challenge
نویسندگان
چکیده
INTRODUCTION The porosity of the fibrous capsule around a glaucoma drainage device (GDD) may be the most important functional attribute. The factors that determine capsular porosity are not well understood. Failed GDD surgeries are usually associated with thick impervious capsules and components of aqueous have been implicated in this process. PURPOSE In this study, we interrogated the effect of passage of nonaqueous fluid on capsular porosity in mature (but aqueous naïve) blebs in a previously reported GDD model (the "Center for Eye Research Australia Implant"). MATERIALS AND METHODS The study was performed at two centers using 17 New Zealand White (NZW) rabbits. An experimental GDD was implanted into the subconjunctival space but without connection to the anterior chamber. After 28 days, balanced salt solution (BSS) was passed through the implant for 30 to 40 minutes at 12 mm Hg. Capsular porosity was measured as flow (μL/min) at a constant pressure. Porosity of the capsule was retested at 3 and 6 days. RESULTS There was a marked reduction in capsular porosity within 3 days of exposure to BSS (fluid challenge). Even though the baseline porosity was significantly different in the two groups (3.00 ± 0.5 μL/min and 29.67 ± 12.12 μL/min, p < 0.001), the effect of passage of BSS was similar. Capsular porosity fell by approximately 80% in both groups from baseline after single BSS challenge. Capsular thickness was significantly less in Advanced Eye Center (AEC) rabbits at baseline. There was no change in the capsular thickness before and after single fluid challenge. CONCLUSION Passage of BSS at physiological pressures for under 40 minutes caused marked reduction in the porosity of the fibrous capsule within 3 days. This was not associated with any significant thickening of the fibrous capsule within this time frame. HOW TO CITE THIS ARTICLE Pandav SS, Ross CM, Thattaruthody F, Nada R, Singh N, Gautam N, Beirne S, Wallace GG, Sherwood MB, Crowston JG, Coote M. Porosity of Bleb Capsule declines rapidly with Fluid Challenge. J Curr Glaucoma Pract 2016;10(3):91-96.
منابع مشابه
Determination of bleb capsule porosity with an experimental glaucoma drainage device and measurement system.
IMPORTANCE Control of intraocular pressure after implantation of a glaucoma drainage device (GDD) depends on the porosity of the capsule that forms around the plate of the GDD. OBJECTIVE To compare capsular porosity after insertion of 2 different GDDs using a novel implant and measurement system. DESIGN, SETTING, AND SUBJECTS We performed an experimental interventional study at an eye resea...
متن کاملEnhanced short-term plasmid transfection of filtration surgery tissues.
PURPOSE To quantify and localize plasmid transfection of filtration surgery tissues using two delivery techniques. METHODS Full-thickness filtering procedures were performed on eyes of New Zealand albino rabbits. In 10 eyes, naked plasmid DNA in saline was either injected beneath Tenon's capsule at the filtration site or absorbed into a collagen shield that was then placed external to the scl...
متن کاملNumerical simulation of effect of non-spherical particle shape and bed size on hydrodynamics of packed beds
Fluid flow has a fundamental role in the performance of packed bed reactors. Some related issues, such as pressure drop, are strongly affected by porosity, so non-spherical particles are used in industry for enhancement or creation of the desired porosity. In this study, the effects of particle shape, size, and porosity of the bed on the hydrodynamics of packed beds are investigated with three ...
متن کاملEvaluation of bleb characteristics after implantation of the EX-PRESS™ glaucoma filtration device
PURPOSE To compare bleb survival and histology after implantation of the EX-PRESS™ glaucoma filtration device versus silicone tubes in a rabbit model of filtration surgery. METHODS Glaucoma filtration surgery was performed on one eye each of twelve New Zealand white rabbits. Eyes were randomized to implantation with the EX-PRESS™ filtration device (n=6) or a silicone tube (n=6). Bleb vascular...
متن کامل5.1. Intraoperative use and needling bleb revision with mitomycin C Intraoperative use and needling bleb revision with mitomycin C
MMC when applied topically or injected subconjunctivally, prevents proliferation of fibroblasts within the subconjunctival space and tenon’s capsule. It also has a lethal effect on vascular endothelial cells. A single application of MMC can cause localized, irreversible inhibition of both fibroblasts and vascular endothelial cells. MMC is estimated to be 100 times more potent than 5-FU in fibro...
متن کامل