On two versions of a 3π algorithm for spiral CT
نویسنده
چکیده
A 3π algorithm is obtained in which all the derivatives are confined to a detector array. Distance weighting of backprojection coefficients of the algorithm is studied. A numerical experiment indicates that avoiding differentiation along the source trajectory improves spatial resolution. Another numerical experiment shows that the terms depending on the non-standard distance weighting 1/|x − y(s)| can no longer be ignored.
منابع مشابه
Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملConventional and spiral CT dose indices in Yazd general hospitals, Iran
ABSTRACT Background: While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiological procedures. Is the reduction of exposures by requiring optimization of CT procedures [a principle concern in radiological protection]? In this study, the radiatio...
متن کاملبررسی دقت سیتیاسکن اسپیرال با بازسازی به روش Multi Planar(MPR) در اندازهگیری طول کلیه در بیمارستان شهید هاشمینژاد در سال 1383
Background & Aim: Measuring the length of kidneys is an important issue in diagnosis and treatment of renal diseases. In various diseases, kidneys become larger or smaller than normal. Ultrasonography is a suitable method for measuring renal length because it is accurate, noninvasive, available and with low cost. Nowadays, multislice spiral CT scanners are widely used for evaluation of rena...
متن کاملAssessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom study
Introduction: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. Materials and Methods: A special wedding cake phantom with circular in...
متن کاملEvaluation of Absorbed Dose of Critical Organ in Rando Phantom under Head, Abdomen and Pelvis Spiral CT Scan by Thermo Luminescent Dosimetery - TLD
Background & Objectives: Computed tomography (CT) represents 11% of all diagnostic radiology procedures but it contributes to almost 67% of the total effective dose to the human population. In head and neck CT which consist of 1/3 of total CT scans, other critical organs such as lenses and thyroid are in the radiation field. Also in the abdomen and pelvis scan, irradiation of ovaries is unavoid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004