Validation of a metered dose inhaler electronic monitoring device: implications for asthma clinical trial use.

نویسندگان

  • Janine Pilcher
  • Mark Holliday
  • Stefan Ebmeier
  • Steve McKinstry
  • Fatiha Messaoudi
  • Mark Weatherall
  • Richard Beasley
چکیده

BACKGROUND The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. METHODS 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. RESULTS 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. CONCLUSIONS The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Validation of a Questionnaire for Assessing Adherence to Metered-Dose Inhaler Use in Asthmatic Children

Maintenance therapies for asthma are vulnerable to low adherence. Clinicians would benefit from having a validated questionnaire to assess adherence to metered-dose inhaler use in children with asthma. The objective of this study was to design and validate a questionnaire assessing adherence to metered-dose inhaler use, to be filled out by the parents and/or caregivers of children with asthma. ...

متن کامل

Three-month validation of a turbuhaler electronic monitoring device: implications for asthma clinical trial use

BACKGROUND Electronic monitoring of inhaled asthma therapy is suggested as the 'gold standard' for measuring patterns of medication use in clinical trials. The SmartTurbo (Adherium (NZ) Ltd, Auckland, New Zealand) is an electronic monitor for use with a turbuhaler device (AstraZeneca, UK). The aim of this study was to determine the accuracy of the SmartTurbo in recording Symbicort actuations ov...

متن کامل

Domiciliary comparison of terbutaline treatment by metered dose inhaler with and without conical spacer in severe and moderately severe chronic asthma.

The bronchodilator response to cumulative doses of terbutaline administered by metered dose inhaler with and without a conical spacer device and by Acorn nebuliser has been compared in groups of patients with chronic severe and moderately severe asthma. After laboratory studies the patients undertook a randomised domiciliary crossover comparison of bronchodilator response to terbutaline given b...

متن کامل

A randomised controlled trial to assess the relative benefits of large volume spacers and nebulisers to treat acute asthma in hospital.

OBJECTIVES To compare the clinical effectiveness, acceptability, and cost benefit of administering beta2 agonists by means of a metered dose inhaler and large volume spacer with conventional nebulisers to children admitted to hospital with acute asthma. METHODS A randomised controlled trial was conducted over five months. Sixty one children older than 3 years admitted to a large teaching hosp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of allergy and clinical immunology

دوره 130 6  شماره 

صفحات  -

تاریخ انتشار 2012