Clinical experience with the Ahmed glaucoma valve implant in complicated glaucoma.

نویسندگان

  • Shiu-Chen Wu
  • Samuel C M Huang
  • Ken-Kuo Lin
چکیده

BACKGROUND To assess clinical outcomes of the Ahmed glaucoma valve implant, an aqueous shunting device with a unidirectional valve mechanism, in eyes with refractory glaucoma. METHODS Consecutive patients with intractable glaucoma who underwent Ahmed glaucoma valve insertion were retrospectively reviewed. Only patients with a minimum of 6 months of follow-up were included. The presence of intraocular pressure (IOP) > or = 22 mmHg in the first 6 postoperative months was defined as a hypertensive phase (HP). This study included 19 eyes in 19 patients. RESULTS The mean preoperative IOP was 32.1 +/- 6.9 mmHg, with medication (mean times medication administered, 3.8 +/- 1.0; range, 0-3). The mean postoperative IOP was 7.8 +/- 2.2 mmHg on day 1, 11.3 +/- 4.4 mmHg at 1 week, 19.1 +/- 7.7 mm Hg at 1 month, 16.5 +/- 6.4 mmHg at 3 months, and 17.5 +/- 0.7 mmHg at 6 months, respectively. Twelve patients (63.2%) exhibited the HP. Nine patients (49.3%) experienced the HP at 1 month and 3 patients at 2 months after the operation. At the end of 6 months of follow-up, 11 patients (57.9%) who had exhibited the HP required additional anti-glaucoma medication to control the IOP (mean times medication was administered, 1.0 +/- 1.1; range, 0-2). Complications associated with the valve included hyphema in 1 case, choroidal effusion in 2 cases, iris plugging of the tube in 1 case, bleb encapsulation in 3 cases, and PK graft failure in 1 case. Postoperative hypotony resolved within 1 week. CONCLUSION The Ahmed glaucoma valve implant was safe and effective in this series. The hypertensive phase peaked in the first to second months after surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ahmed glaucoma valve implant for childhood glaucoma in Sturge-Weber syndrome with choroidal hemangioma.

We present our experience with implantation of an Ahmed glaucoma valve in a 9-year-old girl with Sturge-Weber syndrome with choroidal hemangioma. In this case of childhood glaucoma, the choice of surgical procedure should be based on the efficacy and elimination of intra-and post-operative complications. An Ahmed glaucoma valve offered safety and efficacy in controlling glaucoma. This technique...

متن کامل

Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...

متن کامل

Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.

AIMS To evaluate the efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. METHODS This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. RESULT...

متن کامل

EYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma

Aims—To evaluate the eYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. Methods—This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. Results—A to...

متن کامل

Ahmed glaucoma valve implant: surgical technique and complications

Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chang Gung medical journal

دوره 26 12  شماره 

صفحات  -

تاریخ انتشار 2003