Clinical assessment of the single use laryngeal mask airway--the LMA-unique.
نویسندگان
چکیده
We conducted a clinical comparison of the laryngeal mask airway (LMA) and the new single use PVC LMA (LMA-Unique) in 100 fasted adult patients undergoing elective surgery. Patients were allocated to one of two groups: group 1 (n = 50) was managed by two consultants and group 2 by two trainee anaesthetists. Airway management was randomized prospectively within each group, and cuff pressure in both devices was maintained at a maximum of 50 mm Hg with upward size substitution if leaks persisted during intermittent positive pressure ventilation (IPPV). Insertion with the recommended technique was successful in all patients (85 first attempt). One patient (group 1) required four attempts for insertion of the LMA-Unique and in one patient (group 2) the LMA-Unique was replaced by a tracheal tube because of persistent leaks during IPPV. In 99 patients IPPV was uneventful. The adjusted mean volume of air for cuff inflation in the LMA-Unique was significantly less in group 1 (P = 0.0013). At fibreoptic laryngoscopic examination, the vocal cords or arytenoids, or both, could be seen in 92% of patients in group 1 and in 90% of patients in group 2. Immediate throat soreness was reported in four patients in group 1 and in seven in group 2. The results suggest that the LMA-Unique was similar in clinical performance to the LMA.
منابع مشابه
Limitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملCOMPARISON BETWEEN THE EFFICACY OF TRAPEZIUS SQUEEZING TEST AND JAW THRUST MANEUVER FOR PREDICTION OF SUCCESSFUL INSERTION OF LARYNGEAL MASK AIRWAY
Background & Aims: The aim of this study was to compare trapezius squeezing and jaw thrust to evaluate suitable conditions for laryngeal mask airway (LMA) insertion. Materials & Methods: In this clinical trial study, 138 patients with ASA physical status 1 or 2 who were candidates for elective surgery of shin fracture were randomly assigned into one of the groups of trapezius squeeze and raisi...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملHemodynamic responses to insertion of the laryngeal mask airway versus Combitube
Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 80 5 شماره
صفحات -
تاریخ انتشار 1998